Current Status of Low Intensity Pulsed Ultrasound for Dental Purposes

نویسندگان

  • Emanuel Braga Rego
  • Takashi Takata
  • Kazuo Tanne
  • Eiji Tanaka
چکیده

Over the past few years, tissue engineering applied to the dental field has achieved relevant results. Tissue engineering can be described by actions taken to improve biological functions. Several methods have been described to enhance cellular performance and low intensity pulsed ultrasound (LIPUS) has shown to play an important role in cell metabolism. The present article provides an overview about the current status of LIPUS as a tissue engineering tool to be used to enhance tooth and periodontal regeneration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE BEST DURATION OF LOW INTENSITY PULSED ULTRASOUND FOR ACCELERATING FRACTURED-RADIAL BONE REPAIR

We have already shown that low intensity pulsed ultrasonic treatment increases rabbit radial fracture healing. The present experiment was undertaken to find out the best duration for treatment. A complete transverse fracture was made in the right radial bones of21 adult male rabbits by a Stanley knife. The animals were divided into 4 groups: group 1, control groups 2, 3, and 4, experimental...

متن کامل

LOW INTENSITY PULSED ULTRASOUND TREATMENT INCREASES RABBIT RADIAL FRACTURE HEALING

In order to study the effect of ultrasound (US) on bone healing, a complete transverse fracture was made in the right radius of adult male rabbits by a cutter. 52 rabbits were used: group I. control (n= 17): group 2. test (n:=: 15): group 3, intact (n= I) and group 4 (n= 12) who were examined only for evaluation of the cutter effects in detail. 7 animals were operated with a Gigli saw. The ...

متن کامل

Effects of Low-Intensity Pulsed Ultrasound on Dental Implant Osseointegration: A Preliminary Report

OBJECTIVES The aim of this pilot study was to evaluate the effects of low intensity pulsed ultrasound (LIPU) on dental implant osseointegration in a rabbit model using mechanical-histomorphometric methods and resonance-frequency analysis (RFA). METHODS Twelve skeletally mature, male New Zealand rabbits (3.4 kg+/-0.5) were included in the study. A total number of 24 implants were placed bilate...

متن کامل

Low Intensity Pulsed Ultrasound (LIPUS)

The application of ultrasound energy at much lower levels than is the current clinical norm is starting to gain ground as a therapeutic possibility. Clearly the applied energy is the same, it is the ‘dose’ which is different – most importantly, the intensity (W/cm) – which is MUCH lower – typically 2 or 3 times lower than the lowest setting on most regular clinical machines, with the most commo...

متن کامل

Low Intensity Pulsed Ultrasound (LIPUS)

The application of ultrasound energy at much lower levels than is the current clinical norm is starting to gain ground as a therapeutic possibility. Clearly the applied energy is the same, it is the ‘dose’ which is different – most importantly, the intensity (W cm) – which is MUCH lower – typically 2 or 3 times lower than the lowest setting on most regular clinical machines, with the most commo...