Tackling Oxygen Optode Drift: Near-Surface and In-Air Oxygen Optode Measurements on a Float Provide an Accurate in Situ Reference

نویسندگان

  • HENRY C. BITTIG
  • ARNE KÖRTZINGER
چکیده

A yet unexplained drift of (some) oxygen optodes during storage/transport and thus significant deviations from factory/laboratory calibrations have been a major handicap for autonomous oxygen observations. Optode drift appears to be systematic and is predominantly a slope effect due to reduced oxygen sensitivity. A small contribution comes from a reduced luminophore lifetime, which causes a small positive offset. A reliable in situ reference is essential to correct such a drift. Traditionally, this called for a ship-based reference cast, which poses some challenges for opportunistic float deployments. This study presents an easily implemented alternative using near-surface/in-air measurements of an Aanderaa optode on a 10-cm stalk and compares it to the more traditional approaches (factory, laboratory, and in situ deployment calibration). In-air samples show a systematic bias depending on thewater saturation, which is likely caused by occasional submersions of the standardheight stalk optode. Linear regression ofmeasured in-air supersaturation against in-water supersaturation (using ancillary meteorological data to define the saturation level) robustly removes this bias and thus provides a precise (0.2%) and accurate (1%) in situ correction that is available throughout the entire instrument’s lifetime.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Situ CO2 and O2 Measurements on a Profiling Float

In recent years, profiling floats, which form the basis of the successful international Argo observatory, are also being considered as platforms for marine biogeochemical research. This study showcases the utility of floats as a novel tool for combined gas measurements of CO2 partial pressure (pCO2) and O2. These float prototypes were equipped with a small-sized and submersible pCO2 sensor and ...

متن کامل

An optode sensor array for long-term in situ oxygen measurements in soil and sediment.

Long-term measurements of molecular oxygen (O) dynamics in wetlands are highly relevant for understanding the effects of water level changes on net greenhouse gas budgets in these ecosystems. However, such measurements have been limited due to a lack of suitable measuring equipment. We constructed an O optode sensor array for long-term in situ measurements in soil and sediment. The new device c...

متن کامل

Measurement of cerebral tissue oxygenation in young healthy volunteers during acetazolamide provocation: a transcranial Doppler and near-infrared spectroscopy investigation.

Recent advances in near-infrared spectroscopy (NIRS) allow measurements of absolute tissue oxygen saturation (TOI) using spatially resolved spectroscopy (SRS), while enabling better depth sensitivity. However concerns remain regarding the relative contribution of the extracranial circulation to the cerebral NIRS TOI signal. In this study we investigated this during a period of selective rise in...

متن کامل

Design and Fabrication of a Ratiometric Planar Optode for Simultaneous Imaging of pH and Oxygen

This paper presents a simple, high resolution imaging approach utilizing ratiometric planar optode for simultaneous measurement of dissolved oxygen (DO) and pH. The planar optode comprises a plastic optical film coated with oxygen indicator Platinum(II) octaethylporphyrin (PtOEP) and reference quantum dots (QDs) embedded in polystyrene (PS), pH indicator 5-Hexadecanoylamino-fluorescein (5-Fluor...

متن کامل

High Quality Oxygen Measurements from Profiling Floats: A Promising New Technique

Two state-of-the-art profiling floats were equipped with novel optode-based oceanographic oxygen sensors. Both floats were simultaneously deployed in the central Labrador Sea gyre on 7 September 2003. They drift at a depth of 800 db and perform weekly profiles of temperature, salinity, and oxygen in the upper 2000 m of the water column. The initial results from the first 6 months of operation a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015