Vancomycin monitoring in term newborns: comparison of peak and trough serum concentrations determined by high performance liquid chromatography and fluorescence polarization immunoassay.
نویسندگان
چکیده
INTRODUCTION Peak and trough serum concentrations of vancomycin were determined in term newborn infants with confirmed or suspected Staphylococcus sp sepsis by high performance liquid chromatography and flourescence polarization immunoassay. OBJECTIVE To statistically compare the results of the high performance liquid chromatography and flourescence polarization immunoassay techniques for measuring serum vancomycin concentrations. METHODS Eighteen peak and 20 trough serum samples were assayed for vancomycin concentrations using high performance liquid chromatography and flourescence polarization immunoassay from October 1995 to October 1997. RESULTS The linear correlation coefficients for high performance liquid chromatography and flourescence polarization immunoassay were 0.27 (peak, P = 0.110) and 0.26 (trough, P = 0.1045) respectively, which were not statistically significant. CONCLUSION There was wide variation in serum vancomycin concentrations determined by high performance liquid chromatography as compared with those determined by flourescence polarization immunoassay. There was no recognizable pattern in the variability; in an apparently random fashion, the high performance liquid chromatography measurement was sometimes substantially higher than the flourescence polarization immunoassay measurement, and at other times it was substantially lower.
منابع مشابه
Monitoring the treatment of sepsis with vancomycin in term newborn infants.
UNLABELLED A prospective study was conducted to determine if standardized vancomycin doses could produce adequate serum concentrations in 25 term newborn infants with sepsis. PURPOSE The therapeutic response of neonatal sepsis by Staphylococcus sp. treated with vancomycin was evaluated through serum concentrations of vancomycin, serum bactericidal titers (SBT), and minimum inhibitory concentr...
متن کاملLiquid chromatography and fluorescence polarization immunoassay methods compared for measuring flecainide acetate in serum.
We analyzed 99 patients' serum samples for concentrations of a new antiarrhythmic agent, flecainide acetate, by fluorescence polarization immunoassay (FPIA) and "high-performance" liquid chromatography (HPLC). Within-day and between-day coefficients of variation at concentrations in the low and high ends of the therapeutic range were less than 7% for HPLC and less than 9% for FPIA. There was no...
متن کاملDetermination of blood sirolimus concentrations in liver and kidney transplant recipients using the Innofluor® fluorescence polarization immunoassay: Comparison with the microparticle enzyme immunoassay and high-performance liquid chromatography-ultraviolet method
BACKGROUND Although high-performance liquid chromatography (HPLC) is the method of choice for blood sirolimus determination, the microparticle enzyme immunoassay (MEIA) run on the IMx analyser is widely used in therapeutic monitoring of this immunosuppressant agent. The aim of our study was to evaluate the possible determination of sirolimus using the fluorescence polarization immunoassay (FPIA...
متن کاملEvaluation of an automated fluorescence polarization immunoassay for vancomycin.
An automated fluorescence polarization immunoassay for the determination of vancomycin levels in serum was evaluated. The vancomycin assay is a homogeneous competitive inhibition immunoassay based on changes in fluorescence polarization that occur with antibody binding. This assay was compared with a liquid chromatographic assay and an agar well diffusion bioassay method by using clinical serum...
متن کاملSevere Apnea in a Premature Infant after Accidental Vancomycin Overdose Responsive to Treatment with Exchange Transfusion
Background: Mostly seen toxicities following vancomycin are ototoxicity and nephrotoxicity. We here report a very low birth weight preterm neonate who developed severe episodes of apnea after accidental iatrogenic vancomycin overdose, responsive to treatment with double volume exchange transfusion. Case report: A preterm neonate weighing 1380 grams received two doses of 10-fold of the normal do...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista do Hospital das Clinicas
دوره 56 5 شماره
صفحات -
تاریخ انتشار 2001