Is the cefoxitin disk test reliable enough to detect oxacillin resistance in coagulase-negative staphylococci?
نویسندگان
چکیده
Coagulase-negative staphylococci (CoNS) represent an important etiology of nosocomial bloodstream infections (2, 4, 6). The introduction of empirical treatment has been a crucial step in reducing morbidity and mortality caused by such infections and in controlling the spread of resistant strains (1, 6). It has been advocated that the cefoxitin disk would be more sensitive than the 1g oxacillin disk to predict the oxacillin heteroresistance phenotype among staphylococci (1, 2, 4, 7, 8). Thus, the National Committee for Clinical Laboratory Standards (NCCLS) has recommended its use for detection of oxacillin resistance (7). A total of 5 of 241 (2.2%) CoNS displaying cefoxitin inhibition zones of 25 mm and resistance to oxacillin by disk diffusion test were isolated by the clinical laboratory of the Hospital São Paulo, a tertiary university hospital located in São Paulo, Brazil, during September and October 2004. The bacterial strains were isolated from diverse body sites and referred to the Laboratório Especial de Microbiologia Clı́nica of Universidade Federal de São Paulo for further characterization. The identification of the CoNS was confirmed based on the morphology of bacterial colonies on blood agar, Gram stain, 3% H2O2 catalase and by agglutination tests (Staphytest; PROBAC, São Paulo, Brazil). The strains were tested for coagulase activity by slide tests with rabbit plasma (Difco Laboratories, Detroit, MI). The final identification was carried out using the GPI card Vitek (BioMerieux, Hazelwood, MI). The antimicrobial susceptibility testing of six antimicrobial agents was performed using Etest (AB Biodisk, Solna, Sweden). The results were interpreted according to the NCCLS guidelines (7). Staphylococcus aureus ATCC 25923 and ATCC 29213 were used as quality control strains. The mecA gene was detected by PCR technique according to the method described previously (6). The genetic relatedness of the five CoNS was evaluated by automated ribotyping using the RiboPrinter microbial characterization system (Qualicon, Wilmington, DE). Isolates were considered to belong to the same ribogroup if their similarity coefficients were 0.93. According to the Vitek system, all five isolates were identified as Staphylococcus epidermidis. They were susceptible to linezolid, vancomycin, and teicoplanin. These isolates were confirmed to be resistant to oxacillin and exhibited cefoxitin inhibition zones that were 25 mm, as shown in Table 1. The presence of the mecA gene was detected in all five CoNS, which displayed distinct ribotyping patterns. Oxacillin resistance among staphylococci is caused by expression of penicillin-binding protein 2a (PBP2a), encoded by the mecA gene, which has low binding affinity to all beta-lactam antibiotics available in the clinical practice (1, 2, 3, 4, 5, 9). Detection of oxacillin resistance is complicated because distinct populations of staphylococci express different levels of resistance. Cefoxitin is considered to be a better predictor than oxacillin for the detection of oxacillin heteroresistance because it is a stronger inducer of PBP2a. In addition, it has high affinity for staphylococcal PBP4, and previous experiments have shown a relationship between PBP2, PBP4, and methicillin resistance (2, 4). Many studies have reported that cefoxitin disks had high sensitivities (97.0 to 100.0%) and specificities (99.0 to 100.0%) in detecting heterogeneous populations of oxacillin-resistant staphylococci (2, 4, 9). However, we observed discrepant results between oxacillin and cefoxitin disks when testing CoNS by disk diffusion. Initially, it was thought these CoNS did not belong to S. epidermidis species and did not carry the mecA gene since they had low oxacillin MICs. However, the Vitek system identified these isolates as S. epidermidis, and the presence of the mecA gene was confirmed by PCR in all isolates. The chance of clonality was also discarded, since no genetic relatedness was encountered among the CoNS, refuting the possibility of an outbreak caused by a strain exhibiting an unusual phenotype. In the absence of a national guideline, most of the Brazilian laboratories follow the NCCLS recommendations. In addition, dilution tests are not available at most Brazilian laboratories, and disk diffusion has been the most performed susceptibility technique. If the cefoxitin results were considered instead of the oxacillin results, these CoNS would have been falsely reported as susceptible to oxacillin, with direct implications for the choice of drugs for treatment. Although the number of isolates tested was low in this study, our results show that the detection of low-level methicillin resistance by the cefoxitin disk among CoNS can be problematic. Thus, our results highlight the importance of testing the oxacillin disk or using molecular techniques for detection of the mecA gene (1, 3, 6, 9). Moreover, changes in the NCCLS cefoxitin disk diffusion breakpoints could be useful for screening such isolates, since all CoNS tested had cefoxitin zones of inhibition between 26 and 29 mm. To increase the sensitivity and specificity of the cefoxitin disk to detect oxacillin heteroresistance among S. aureus, other authors have also suggested changes in the interpretative zone diameters of cefoxitin (4, 9).
منابع مشابه
Identification and detection of methicillin resistance in non-epidermidis coagulase-negative staphylococci.
The NCCLS (2004) presented a new methodology to detect, by disk-diffusion agar, oxacillin-resistance using a cefoxitin disk. We identified coagulase-negative staphylococci (SCoN) to the species level and compared the use of cefoxitin disks (30 microg) with oxacillin disks (1 microg), agar dilution (minimum inhibitory concentration of oxacillin) and mecA gene detection in isolates of coagulase-n...
متن کاملDifferentiationo Methicillin-Resistant and Methicillin-Susceptible Staphylococcus Aureus and Coagulase-Negative Staphylococci using Cefoxitin
Detection of the mecA gene or PBP2a is considered the gold standard for detecting mecA-mediated methicillin resistance in staphylococci. Among available phenotypic methods, the Clinical and Laboratory Standards Institute (CLSI) has introduced the cefoxitin disk diffusion (DD) test for predicting the presence of mecA in S. aureus and CoNS, which is preferred over the oxacillin DD test. Automated...
متن کاملDetection of methicillin-resistant coagulase-negative staphylococci by the Vitek 2 system.
The accurate performance of the Vitek 2 GP67 card for detecting methicillin-resistant coagulase-negative staphylococci (CoNS) is not known. We prospectively determined the ability of the Vitek 2 GP67 card to accurately detect methicillin-resistant CoNS, with mecA PCR results used as the gold standard for a 4-month period in 2012. Included in the study were 240 consecutively collected nonduplica...
متن کاملPerformance of different phenotypic tests in detecting mecA mediated methicillin resistance in Coagulase negative staphylococci (CoNS)
Accurate detection of methicillin resistance (MR) in coagulase negative staphylococci (CoNS) is of utmost importance as infections due to CoNS are on the rise. Various phenotypic methods have been described for detecting mecA mediated MR with varying performance characteristics. The present study was designed to evaluate the performance of oxacillin and cefoxitin disc diffusion / MIC test and o...
متن کاملComparison of tests to detect oxacillin resistance in Staphylococcus intermedius, Staphylococcus schleiferi, and Staphylococcus aureus isolates from canine hosts.
Multiple tests were compared to the reference standard PBP2a latex agglutination test for detection of mecA-mediated oxacillin resistance in canine staphylococci. Cefoxitin disk diffusion, using breakpoints for human isolates of coagulase-negative Staphylococcus spp., had low sensitivity for detection of oxacillin resistance in members of the Staphylococcus intermedius group.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 43 4 شماره
صفحات -
تاریخ انتشار 2005