Zr and U determination at trace level in simulated deep groundwater by Q ICP-MS using extraction chromatography.

نویسندگان

  • C Gautier
  • M Coppo
  • C Caussignac
  • I Laszak
  • P Fichet
  • F Goutelard
چکیده

In the framework of trace element analysis by Q ICP-MS in a simulated deep Callovo-Oxfordian groundwater, separation procedures based on extraction chromatography were developed to eliminate the high salt contents and to concentrate Zr and U simultaneously. Theoretical and experimental speciation studies showed the importance of adjusting the medium to HNO₃/HF (0.5 M/0.005 M) to guarantee the stability over time of the analytes before removal of the matrix. Two preconcentration methods based on TRU and TODGA resins were optimized for the simultaneous isolation of Zr and U prior to Q ICP-MS measurements. Using TRU resin, alkali and alkali earth metals contained in the deep groundwater were removed with 2 M HNO₃ whereas Zr and U were recovered with a HNO₃/NH₄HC₂O₄ (0.02 M/0.05 M) medium. For the separation protocol based on TODGA resin, alkali and alkali earth metals were eliminated with 3 M and 11 M HNO₃ while Zr and U were simultaneously stripped with a HNO₃/HF (0.5 M/0.2 M) medium. The procedure optimized on TODGA resin was validated with the French AFNOR NF T90-210 standard by studying linearity, limits of quantification (LOQ) and separation yields. The LOQ was determined at 0.008 μg L(-1) for Zr and U after the separation. Both analytes were recovered quantitatively. Compared to a sample dilution implemented to reduce the matrix effects, the developed preconcentration method allowed improving the sensitivity up to a 20 fold factor for Zr and U measurements at trace level by Q ICP-MS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multielement determination and speciation of major-to-trace elements in black tea leaves by ICP-AES and ICP-MS with the aid of size exclusion chromatography.

A multielement determination of major-to-trace elements in black tea leaves and their tea infusions was carried out by ICP-AES (inductively coupled plasma atomic emission spectrometry) and ICP-MS (inductively coupled plasma mass spectrometry). Tea infusions were prepared as usual tea beverage by brewing black tea leaves in boiling water for 5 min. About 40 elements in tea leaves and tea infusio...

متن کامل

An accurate and sensitive method for the determination of methylmercury in biological specimens using GC-ICP-MS with solid phase microextractionw

A highly sensitive and selective method has been developed for the determination of methylmercury in biological specimens and NIST Standard Reference Materials (SRMs). The procedure involves microwave extraction with acetic acid, followed by derivatization and headspace solid-phase microextraction (SPME) with a polydimethylsiloxane (PDMS)-coated silica fiber. Optimization of conditions includin...

متن کامل

Human Health Risk Assessment of Nitrate and Trace Metals Via Groundwater in Central Bangladesh

Groundwater plays a pivotal role as the largest potable water sources in Bangladesh. As agriculture is widely practiced in Bangladesh, potential nitrate (NO3¯) pollution may occur. Besides, excess amount of arsenic (As) has already been found in groundwater in many parts of Bangladesh including the present study area. Thus, this study was conducted to assess the NO3¯ status along with some trac...

متن کامل

Human Health Risk Assessment of Nitrate and Trace Metals Via Groundwater in Central Bangladesh

Groundwater plays a pivotal role as the largest potable water sources in Bangladesh. As agriculture is widely practiced in Bangladesh, potential nitrate (NO3¯) pollution may occur. Besides, excess amount of arsenic (As) has already been found in groundwater in many parts of Bangladesh including the present study area. Thus, this study was conducted to assess the NO3¯ status along with some trac...

متن کامل

Determination of Aflatoxins B1 and B2 in Powdered Milk Using Modified Liquid Chromatography Method

Background & Aims: In this study, using a liquid-liquid microextraction method for pre-concentration trace amounts of aflatoxins, the amount of Aflatoxins B1 and B2 in powdered milk was determined. Determination of aflatoxins was done by using high-performance liquid chromatography coupled with fluorescent detector. Method: Samples were extracted by immunoaffinity column (IAC) clean-up, and the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 106  شماره 

صفحات  -

تاریخ انتشار 2013