A universal transvaginal cervical length screening program for preterm birth prevention.

نویسندگان

  • Kelly M Orzechowski
  • Rupsa C Boelig
  • Jason K Baxter
  • Vincenzo Berghella
چکیده

OBJECTIVE To evaluate a universal transvaginal ultrasonogram cervical length screening program on the incidence of a cervical length 20 mm or less and adherence to the management protocol for a cervical length less than 25 mm. METHODS We conducted a prospective cohort study of women with singleton gestations 18 0/7 to 23 6/7 weeks of gestation eligible for universal transvaginal ultrasonogram cervical length screening over an 18-month period. Only women receiving antenatal care at our institution were included. Women with a prior spontaneous preterm birth and without delivery data available were excluded. A transvaginal ultrasonogram cervical length of less than 25 mm was managed according to a predetermined protocol. Primary outcomes were the incidence of a cervical length 20 mm or less and adherence to the management protocol for a cervical length less than 25 mm. Secondary outcomes were the incidences of spontaneous preterm birth at less than 37, less than 34, or less than 32 weeks of gestation among women undergoing transvaginal ultrasonogram cervical length screening compared with those not screened. RESULTS One thousand five hundred sixty-nine of 2,171 (72.3%) eligible women underwent transvaginal ultrasonogram cervical length screening. Overall, 17 (1.1%, 95% confidence interval [CI] 0.66-1.74) women had a cervical length 20 mm or less before 24 weeks of gestation. Management protocol deviations occurred in nine women with a cervical length less than 25 mm (43%, 95% CI 24.3-63.5). There was no difference in the incidence of spontaneous preterm birth at less than 37 weeks of gestation (4.1 compared with 4.7%, adjusted odds ratio [OR] 0.91, 95% CI 0.57-1.45), less than 34 weeks of gestation (1.5 compared with 1.3%, adjusted OR 1.19, 95% CI 0.52-2.74), or less than 32 weeks of gestation (0.8 compared with 0.8%, adjusted OR 0.0.76, 95% CI 0.26-2.25) among women receiving transvaginal ultrasonogram cervical length screening compared with those not screened. CONCLUSION In a universal transvaginal ultrasonogram cervical length screening program, the incidence of a cervical length 20 mm or less was 1.1% in women with singleton gestations without prior spontaneous preterm birth. Protocol deviations occurred in 43% of women with a cervical length less than 25 mm. The incidence of spontaneous preterm birth was similar among women undergoing transvaginal cervical length screening compared with those not screened. LEVEL OF EVIEDENCE: II.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Universal cervical-length screening to prevent preterm birth: a cost-effectiveness analysis.

OBJECTIVE To determine whether routine measurement of second-trimester transvaginal cervical length by ultrasound in low-risk singleton pregnancies is a cost-effective strategy. METHODS We developed a decision analysis model to compare the cost-effectiveness of two strategies for identifying pregnancies at risk for preterm birth: (1) no routine cervical length screening and (2) a single routi...

متن کامل

Vaginal progesterone in risk reduction of preterm birth in women with short cervix in the midtrimester of pregnancy

Preterm birth is a major health problem for the neonate, family, country, and society in general. Despite many risk factors being identified for women destined to deliver preterm, short cervical length detected on transvaginal ultrasound is the most plausible, practical and sensitive risk factor for prediction of spontaneous preterm birth. The definition of short cervix has varied in various st...

متن کامل

Transvaginal sonographic measurement of cervical length and the risk of spontaneous preterm birth

Transvaginal sonographic measurement of cervical length, at 20 weeks of gestation, is very useful to predict spontaneous preterm birth. A large number of studies have been performed in the attempt to detect the spontaneous preterm birth on the basis of biological, biochemical and ultrasound parameters. Transvaginal Sonography is a good tool to evaluate the cervix. This study aims to evaluate th...

متن کامل

The Effect of a Universal Cervical Length Screening Program on Antepartum Management and Birth Outcomes

Objective The objective of this study was to evaluate the effect of a universal cervical length screening program on the incidence of antepartum interventions. Study Design This retrospective cohort study included women delivering ≥ 20 weeks of gestation with singleton pregnancies before and after implementing universal cervical length screening. Antepartum interventions included admission for ...

متن کامل

Progesterone and preterm birth prevention: translating clinical trials data into clinical practice.

OBJECTIVE We sought to provide evidence-based guidelines for using progestogens for the prevention of preterm birth (PTB). METHODS Relevant documents, in particular randomized trials, were identified using PubMed (US National Library of Medicine, 1983 through February 2012) publications, written in English, which evaluate the effectiveness of progestogens for prevention of PTB. Progestogens e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Obstetrics and gynecology

دوره 124 3  شماره 

صفحات  -

تاریخ انتشار 2014