In vitro study on the disinfectability of two split-septum needle-free connection devices using different disinfection procedures

نویسندگان

  • Steffen Engelhart
  • Martin Exner
  • Arne Simon
چکیده

This in vitro study investigated the external disinfection of two needle-free connection devices (NFC) using Octeniderm(®) (spraying and wiping technique) vs. Descoderm(®) pads (wiping technique). The split-septum membrane of the NFC was contaminated with >10(5) CFU K. pneumoniae or S. epidermidis. The efficacy of the disinfection at 30 sec. exposure time was controlled by taking a swab sample and by flushing the NFC with sterile 0.9% sodium chloride solution. Disinfection with octenidine dihydrochloride 0.1 g, 1-Propanol 30.0 g, and 2-Propanol 45.0 g in 100 g solution was highly effective (CFU reduction ≥4 log) against both microorganisms, whereas the use of 63.1 g 2-Propanol in 100 ml solution led to residual contamination with S. epidermidis. Our investigation underlines that (i) in clinical practice disinfection of NFCs before use is mandatory, and that (ii) details of disinfection technique are of utmost importance regarding their efficacy. Our investigation revealed no significant differences between both split-septum NFC types. Clinical studies are needed to confirm a possible superiority of disinfectants with long-lasting residual antimicrobial activity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه تأثیر ضدعفونی با الکل ایزوپروپیل و اتانول بر کاهش میزان آلودگی وسایل معاینه پزشکی

Background & Aim: Hospital infections are still one of the main causes of death. These infections may be transferred from one patient to another or through medical devices. The prevalence of hospital-acquired infection is 6%-12%. This rate increases to about 65% in some underdeveloped countries. The goal of this study was to compare the efficacy of Isopropyl alcohol and Ethanol in disinfection ...

متن کامل

Thermal and Surface Changes of Dental Implants Following Use of Rotary Instruments and Piezoelectric Devices for Implantoplasty: An In-Vitro Study

  Objective: Peri-implantitis is an irreversible inflammatory reaction in the soft and hard tissues around a functional implant . One of the treatment approaches of this disease include smoothing and polishing the rough surface and removing threads on the implants using rotary instruments, which is called implantoplasy. Clinicians should perform implantoplasty with caution because it may raise ...

متن کامل

Connection Interface Designing for Grid and Mobile Devices

There area lot of mobile computer devices with a variety of applications and users Tend to use them more. Due to the limitations of mobile devices, running most of the procedures are impossible. To resolve this problem, mobile devices can be connected to the grid, to use the facilities of grid. On the other hand the communication mechanisms are different for each device and they cannot be c...

متن کامل

Connection Interface Designing for Grid and Mobile Devices

There area lot of mobile computer devices with a variety of applications and users Tend to use them more. Due to the limitations of mobile devices, running most of the procedures are impossible. To resolve this problem, mobile devices can be connected to the grid, to use the facilities of grid. On the other hand the communication mechanisms are different for each device and they cannot be c...

متن کامل

How much is red blood cell fragmentation increased by the use of closed luer lock access devices on catheter hubs?

The opening and manipulation of central venous (CV) catheters before and after each dialysis event might result in catheter-related blood stream infections [1–3]. In order to reduce those infection risks, different types of closed luer lock access devices are commercially available. Such connectors are placed on the arterial and venous catheter hub and are designed with a split septum of medica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015