Characteristic Analysis of DS18B20 Temperature Sensor in the High-voltage Transmission Lines’ Dynamic Capacity Increase
نویسندگان
چکیده
Dynamic capacity increase in high voltage electric power transmission line is currently the most economical method for solving electric power transmission bottleneck nowadays. DS18B20 temperature sensor is applied to the dynamic capacity increase of high voltage transmission lines to measure the conductor temperature and ambient temperature. The paper is focused on the experiment of DS18B20 both in the laboratory and outside. From the result of the lab temperature measurement data analysis, using 4 DS18B20’s is the most suitable plan, considering both accuracy and economical efficiency. In the experiment outside, we get four groups of conductor (uncharged) temperature and four groups of ambient temperature. The data proved that DS18B20 has good stability, and small measurement error. It is suitable for measuring the temperature of conductor and ambient in dynamic capacity increase, and helpful to improve the accuracy of the calculation of capacity increasing.
منابع مشابه
A Novel Method to Increase the Power Capacity of Transmission Lines Using Transformerless Static Synchronous Series Compensator
In this paper a transformerless Static Synchronous Series Compensator (SSSC) to increase the power capacity of a 230 kV transmission line is proposed. In order to eliminate the transformer, a 15-level cascade H Bridge (CHB) inverter is employed within the proposed compensator structure to inject reactive power to the transmission line. The theory of instantaneous p-q power using in the compensa...
متن کاملDesign of Wireless Temperature Measuring System Based on the nRF24l01
Wireless data transmission system which composed of wireless data transmission device nRF24L01, temperature sensor [DS18B20,] and STC89C52. The system can collect and transmit temperature information and display it on LED, when the temperature excess the set value, the system will alarm by the buzzer. The hardware and software of the design are explained in detail. Finally, the application of t...
متن کاملFault Locating in High Voltage Transmission Lines Based on Harmonic Components of One-end Voltage Using Random Forests
In this paper, an approach is proposed for accurate locating of single phase faults in transmission lines using voltage signals measured at one-end. In this method, harmonic components of the voltage signals are extracted through Discrete Fourier Transform (DFT) and are normalized by a transformation. The proposed fault locator, which is designed based on Random Forests (RF) algorithm, is train...
متن کاملOptimal Location and Parameter Settings of UPFC Device in Transmission System based on Imperialistic Competitive Algorithm
In this paper, we present a new method to determine the optimal location and parameter settings of UnifiedPower Flow Controller (UPFC) for removing voltage violations and transmission lines overloading. UPFC isconsidered as the most powerful member of the FACTS devices, that it can control shunt and series power flow.This option gives to UPFC the power to control the voltage profile and transmi...
متن کاملA new control strategy for SSSC to improve low-frequency oscillations damping
When power systems are expanded and connected together with weak tie lines, the low-frequency oscillations are increased and the stability margin of the power system decreases. Therefore, when designing the transmission system to be used, it is necessary to maintain the dynamic stability of the power system, and to make sure to have the most possible stability margin. SSSC is a FACTS device con...
متن کامل