Predicting mouse vertebra strength with micro-computed tomography-derived finite element analysis.
نویسندگان
چکیده
As in clinical studies, finite element analysis (FEA) developed from computed tomography (CT) images of bones are useful in pre-clinical rodent studies assessing treatment effects on vertebral body (VB) strength. Since strength predictions from microCT-derived FEAs (μFEA) have not been validated against experimental measurements of mouse VB strength, a parametric analysis exploring material and failure definitions was performed to determine whether elastic μFEAs with linear failure criteria could reasonably assess VB strength in two studies, treatment and genetic, with differences in bone volume fraction between the control and the experimental groups. VBs were scanned with a 12-μm voxel size, and voxels were directly converted to 8-node, hexahedral elements. The coefficient of determination or R (2) between predicted VB strength and experimental VB strength, as determined from compression tests, was 62.3% for the treatment study and 85.3% for the genetic study when using a homogenous tissue modulus (E t) of 18 GPa for all elements, a failure volume of 2%, and an equivalent failure strain of 0.007. The difference between prediction and measurement (that is, error) increased when lowering the failure volume to 0.1% or increasing it to 4%. Using inhomogeneous tissue density-specific moduli improved the R (2) between predicted and experimental strength when compared with uniform E t=18 GPa. Also, the optimum failure volume is higher for the inhomogeneous than for the homogeneous material definition. Regardless of model assumptions, μFEA can assess differences in murine VB strength between experimental groups when the expected difference in strength is at least 20%.
منابع مشابه
Prediction of Human Vertebral Compressive Strength Using Quantitative Computed Tomography Based Nonlinear Finite Element Method
Introduction: Because of the importance of vertebral compressive fracture (VCF) role in increasing the patients’ death rate and reducing their quality of life, many studies have been conducted for a noninvasive prediction of vertebral compressive strength based on bone mineral density (BMD) determination and recently finite element analysis. In this study, QCT-voxel based nonlinear finite eleme...
متن کاملPredicting strengths of the femur and vertebra in patients with postmenopausal osteoporosis by a CT based finite element method - The predicted fracture load of the proximal femur is correlated with that of the lumber vertebra -
Introduction: Clinically available methods for estimating bone strength include bone densitometry techniques such as dual energy X-ray absorptiometry and peripheral quantitative computed tomography, and other diagnostic imaging procedures such as radiographic imaging. These techniques evaluate regional bone density and morphology, which are partly related to fracture risk, but are of limited va...
متن کاملBiomechanical assessment of new surgical method instead of kyphoplasty to improve the mechanical behavior of the vertebra: Micro finite element study
AIM To reduce post treatments of kyphoplasty, as a common treatment for osteoporotic vertebrae. METHODS This study suggests a new method for treating vertebrae by setting the hexagonal porous structure instead of the rigid bone cement mass in the kyphoplasty (KP). The KP procedure was performed on the fresh ovine vertebra of the level L1. Micro finite element modeling was performed based on m...
متن کاملMulti-Scale Modeling of the Human Vertebral Body: Comparison of Micro-CT Based High-Resolution and Continuum-Level Models
The overall goal of this study was to assess the mechanistic fidelity of continuum-level finite element models of the vertebral body, which represent a promising tool for understanding and predicting clinical fracture risk. Two finite element (FE) models were generated from micro-CT scans of each of 13 T9 vertebral bodies--a micro-FE model at 60-micron resolution and a coarsened, continuum-leve...
متن کاملInfluence of Vertical Trabeculae on the Compressive Strength of the Human Vertebra
Vertebral strength, a key etiologic factor of osteoporotic fracture, may be affected by the relative amount of vertically oriented trabeculae. To better understand this issue, we performed experimental compression testing, high-resolution micro-computed tomography (µCT), and micro-finite-element analysis on 16 elderly human thoracic ninth (T(9)) whole vertebral bodies (ages 77.5 ± 10.1 years). ...