New Active Input Current Shapers to Allow AC-to-DC Converters With Asymmetrically Driven Transformers to Comply With the IEC-1000-3-2
نویسندگان
چکیده
Four new topologies of active input current shapers (AICSs) for converters with symmetrically driven transformers (such as half-bridge, full-bridge and push-pull) have recently been proposed. This paper analyzes the extension of the use of these new AICSs topologies to converters with asymmetrically driven transformers. Using some of these topologies, the size of AICS inductors can be reduced and even integrated in a single magnetic core. As in the case of other converters with AICS circuit, the new topologies allow line current harmonics to be reduced and thereby to comply with the IEC 1000-3-2 specifications, whilst maintaining all the features of standard dc-to-dc converters (e.g., fast transient response). Finally, the proposed topologies have been experimentally tested.
منابع مشابه
Low-power flyback converter with synchronous rectification for a system with AC power distribution
IEC 1000-3-2 regulations impose a reduced harmonic content on any converter with an input power higher than 75 W. However, if the power architecture of the system is based on small on-board converters, and the total power is higher than 75 W, IEC regulations must be fulfilled although each individual converter need not comply with the regulations. In this paper, one of the different possible so...
متن کاملNovel Three-Level Converter forPower-Factor-Correction and Connected To DC Drive
Abstract: Harmonic pollution and low power factor in power systems caused by power converters have been of great concern. To overcome these problems several converter topologies using advanced semiconductor devices and control schemes have been proposed. In this paper a new three-level ac–dc single-stage converter that can operate with standard phase-shift pulse width modulation is proposed.The...
متن کاملA New Pulsating Power Elimination Method for Single-Phase PWM AC/DC Converters with Minimum Voltage and Current Stress
An inherent problem of single-phase rectifiers is the existence of a pulsating portion in the input power, which pulsates at twice the grid frequency. If this pulsating power is transferred to the DC-link, it causes a significant amount of second-order harmonic at the output voltage. Since in many applications, such a high level of DC oscillation is not acceptable, so the pulsating power must b...
متن کاملZero-current-transition Converters for High-power-factor Ac/dc Applications
Zero-current-transition, discontinuousconduction-mode (ZCT-DCM) converters are introduced in this paper. Compared to hard-switching (PWM) converters in DCM, the ZCT-DCM converters have similar current stresses and conduction losses, and much reduced turn-off switching losses. At the expense of increased voltage stresses, zerocurrent/zero-voltage switching is maintained for a wide range of loads...
متن کاملEfficient low-voltage ride-through nonlinear backstepping control strategy for PMSG-based wind turbine during the grid faults
This paper presents a new nonlinear backstepping controller for a direct-driven permanent magnet synchronous generator-based wind turbine, which is connected to the power system via back-to-back converters. The proposed controller deals with maximum power point tracking (MPPT) in normal condition and enhances the low-voltage ride-through (LVRT) capability in fault conditions. In this method, to...
متن کامل