Added value of one-view breast tomosynthesis combined with digital mammography according to reader experience.

نویسندگان

  • Isabelle Thomassin-Naggara
  • Nicolas Perrot
  • Sophie Dechoux
  • Carine Ribeiro
  • Jocelyne Chopier
  • Cedric de Bazelaire
چکیده

PURPOSE To retrospectively evaluate the added value of one-view breast tomosynthesis in adjunct with mammography to characterize breast lesions. MATERIALS AND METHODS Our institutional ethics committees approved the study and granted a waiver of informed consent. One hundred fifty-five women (mean age, 51.3 years, range: 24-92 years) who systematically underwent mammography and breast tomosynthesis with subsequent percutaneous biopsy were analyzed. Four radiologists (two seniors, R1 and R2, and two juniors, R3 and R4 with 30, 10, 3 and 1 years of experience in breast imaging, respectively) independently reviewed exams in two steps: mammography alone and tomosynthesis in adjunct with mammography. The lesions in the cohort included 39.3% (61/155) cancers, 2.5% (4/155) high-risk lesions and 58.1% (90/155) benign lesions. A receiver operating characteristic (ROC) curve analysis was performed to compare the results of the two readings. RESULTS There was almost perfect agreement irrespective of reader experience for the reading of the mammography in adjunct with tomosynthesis, whereas agreement was poor between junior and senior readers for the reading of mammography alone. Area under the ROC (Az) values for the tomosynthesis in adjunct with mammography were significantly better than Az values for mammography alone for all readers except the most experienced, for whom only a tendency was noted. The proportion of cancers undiagnosed by mammography alone that were well diagnosed by tomosynthesis in adjunct with mammography was 6.5% (4/61), 13.1% (8/61), 27.8% (17/61) and 26.2% (16/61) for Readers 1, 2, 3 and 4, respectively. The proportion of false positive cases induced by the addition of breast tomosynthesis to mammography was 2.1% (2/94), 2.1% (2/94), 9.5% (9/94) and 12.7% (12/94) for Readers 1, 2, 3 and 4, respectively. CONCLUSION Adding breast tomosynthesis to mammography improved sensitivity and negative predictive value for all readers except for the most experienced one, in whom only a tendency for improvement was noted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Addition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations.

PURPOSE To determine the effect of implementing a screening tomosynthesis program on real-world clinical performance by quantifying differences between interpretation times for conventional screening mammography and combined tomosynthesis and mammography for multiple participating radiologists with a wide range of experience in a large academic center. MATERIALS AND METHODS In this HIPAA-comp...

متن کامل

Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU

Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...

متن کامل

Visualization of Breast Microcalcifications on Digital Breast Tomosynthesis and 2-Dimensional Digital Mammography Using Specimens

PURPOSE The purpose of this study is to compare the visibility of microcalcifications of digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM) using breast specimens. MATERIALS AND METHODS Thirty-one specimens' DBT and FFDM were retrospectively reviewed by four readers. RESULTS The image quality of microcalcifications of DBT was rated as superior or equivalent in 71.0...

متن کامل

Digital mammography and tomosynthesis for breast cancer diagnosis.

INTRODUCTION Mammography is one of the most common X-ray examinations although it is well-known that the anatomical background of the breast is the main obstacle when it comes to detection of breast lesions with this method. Tomosynthesis is a three-dimensional radiographic technique which, to a large extent, can suppress the confounding effect of the anatomical background. Tomosynthesis is a s...

متن کامل

Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program.

PURPOSE To assess cancer detection rates, false-positive rates before arbitration, positive predictive values for women recalled after arbitration, and the type of cancers detected with use of digital mammography alone and combined with tomosynthesis in a large prospective screening trial. MATERIALS AND METHODS A prospective, reader- and modality-balanced screening study of participants under...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of radiology

دوره 84 2  شماره 

صفحات  -

تاریخ انتشار 2015