Evaluation of cyanoacrylate augmentation of transpedicular screw pullout strength.

نویسندگان

  • Abtullah Milcan
  • Irfan Ayan
  • Adalet Zeren
  • Tamer Sinmazcelik
  • Ali Yilmaz
  • Muzaffer Zeren
  • Fehmi Kuyurtar
چکیده

PURPOSE Pedicle screw fixation of osteoporotic bone in the elderly is a challenge. Various augmentation methods have been studied by many authors. Although polymethylmethacrylate (PMMA) augmentation is believed to be a standard method, its usage is fraught with complications. Butyl-2-cyanoacrylate is an alternative to PMMA as it is bioresorbable, biocompatible, inexpensive, and noninfective. The objective of the current study was to determine the pullout strength of the pedicle screws when butyl-2-cyanoacrylate is used for augmentation. METHODS Fresh calf lumbar vertebrae were obtained from male calves weighing 100-120 kg and implanted with pedicle screws. The screws were placed in native, unaugmented bone (group 1), butyl-2-cyanoacrylate-augmented bone (group 2), and PMMA-augmented bone (group 3). Axial pullout tests were done by an Instron 4411 universal testing machine. Statistical analysis was performed using the SPSS 9.0 for Windows program. Paired samples t test was used, and P < 0.05 was considered significant. RESULTS The mean bone mineral density of the vertebrae was 1.6 +/- 0.1 g/cm2. The mean pullout strengths were 1.55 +/- 0.23 kN for group 1, 1.62 +/- 0.42 kN for group 2, and 2.55 +/- 0.22 kN for group 3. There was no statistically significant difference between groups 1 and 2. PMMA augmentation increased the pullout strength significantly when compared with butyl-2-cyanoacrylate augmentation and native bone (P = 0.002 and P = 0.001, respectively). CONCLUSIONS The results of this study show that butyl-2-cyanoacrylate has no contribution to the augmentation of pedicle screw fixation in a calf model when compared with native bone or PMMA augmentation. Further studies are required to evaluate the effectiveness of butyl-2-cyanoacrylate in osteoporotic specimens and under cyclic loading in calf vertebra and animal and cadaver models before dispensing with its utility as an augmentation method in the clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pullout Strength after Expandable Polymethylmethacrylate Transpedicular Screw Augmentation for Pedicle Screw Loosening

OBJECTIVE Pedicle screw fixation for spine arthrodesis is a useful procedure for the treatment of spinal disorders. However, instrument failure often occurs, and pedicle screw loosening is the initial step of a range of complications. The authors recently used a modified transpedicular polymethylmethacrylate (PMMA) screw augmentation technique to overcome pedicle screw loosening. Here, they rep...

متن کامل

The Comparison of Pullout Strengths of Various Pedicle Screw Designs on Synthetic Foams and Ovine Vertebrae.

AIM One of the most common problems with transpedicular screws is screw pullout. This study was conducted to measure the pullout strengths of newly designed transpedicular screws. MATERIAL AND METHODS The design of the three group screws were conical cored standard pedicle screw (Type A), dual threaded pedicle screw (Type B), dual core and dual threaded pedicle screw (Type C), respectively. P...

متن کامل

Variability of the pullout strength of cancellous bone screws with cement augmentation.

BACKGROUND Orthopaedic surgeons often face clinical situations where improved screw holding power in cancellous bone is needed. Injectable calcium phosphate cements are one option to enhance fixation. METHODS Paired screw pullout tests were undertaken in which human cadaver bone was augmented with calcium phosphate cement. A finite element model was used to investigate sensitivity to screw po...

متن کامل

A Biomechanical Comparison of Expansive Pedicle Screws for Severe Osteoporosis: The Effects of Screw Design and Cement Augmentation

Expansive pedicle screws significantly improve fixation strength in osteoporotic spines. However, the previous literature does not adequately address the effects of the number of lengthwise slits and the extent of screw expansion on the strength of the bone/screw interface when expansive screws are used with or without cement augmentation. Herein, four designs for expansive pedicle screws with ...

متن کامل

Comparison of the Pullout Strength of Different Pedicle Screw Designs and Augmentation Techniques in an Osteoporotic Bone Model

Study Design Mechanical study. Purpose To compare the pullout strength of different screw designs and augmentation techniques in an osteoporotic bone model. Overview of Literature Adequate bone screw pullout strength is a common problem among osteoporotic patients. Various screw designs and augmentation techniques have been developed to improve the biomechanical characteristics of the bone-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of spinal disorders & techniques

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2005