The effect of photobleaching and velocity fluctuations on single-point LIF measurements

نویسنده

  • J. P. Crimaldi
چکیده

This study investigates the effect of photobleaching on laser-induced fluorescence (LIF) measurements. Photobleaching causes the fluorescence to be velocity-dependent, which is undesirable if quantitative measurements are being made. To quantify this effect, simultaneous and coincident measurements of fluorescence and velocity were made within the measuring volume of a three-beam laser-Doppler anemometer (LDA), using both fluorescein and rhodamine 6G dyes in water. In addition, analytical expressions were developed for photobleaching in the LDA measuring volume, and a parameter was identified which predicts the degree of velocity sensitivity. Fluorescein was found to be far more susceptible to photobleaching than rhodamine 6G. Finally, the impact of photobleaching on statistical quantities (such as scalar fluxes) obtained from simultaneous LDA/LIF measurements is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous whole-field measurements of velocity and concentration fields using a combination of MTV and LIF

A new technique for the simultaneous measurement of velocity and concentration fields is described. We describe here applications in liquid-phase flows, but the methodology can be extended to gas-phase flows with appropriate tracers. In this single-laser, two-tracer approach, molecular tagging velocimetry (MTV) based on the use of a phosphorescent compound is combined with laser induced fluores...

متن کامل

Effect of velocity on microdroplet fluorescence quantified by laser-induced fluorescence.

Microdroplets generated inside microfluidic devices have been widely used as miniaturized chemical and biological reactors allowing important reductions in experimental fluid volumes and making it possible to carry out high-throughput assays. Laser-induced fluorescence (LIF) is commonly used to detect and quantify the product, marker or cell content inside each individual droplet. In this work,...

متن کامل

Comparison of PIV and LDA Measurement Methods Applied to the Gas-Liquid Flow in a Bubble Column

In this work a comparison of multiphase PIV and LDA measurement methods is made. The objective of the work is twofold: to provide measurement results that can be used to validate multiphase CFD simulations and to assess the different acquisition and analysis methods in multiphase measurements. The former is done with the use of a two-camera PIV/LIF method. It is shown that this method gives det...

متن کامل

Mixing of the Immiscible Liquids in the Entrance Region of a T-Type Chamber Using Laser Induced Fluorescence (LIF) Method

A Laser Induced Fluorescence technique (LIF) has been used to study the mixing behavior of two emerging streams in a T-Type mixing chamber. A mixing index on the basis of digital image light intensities is calculated. It has been shown that averaging over more than 800 images leads to a stable mixing index calculation. Moreover, the effect of equal and un-equal flow rates on the mixing behavior...

متن کامل

Fixed-point FPGA Implementation of a Kalman Filter for Range and Velocity Estimation of Moving Targets

Tracking filters are extensively used within object tracking systems in order to provide consecutive smooth estimations of position and velocity of the object with minimum error. Namely, Kalman filter and its numerous variants are widely known as simple yet effective linear tracking filters in many diverse applications. In this paper, an effective method is proposed for designing and implementa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997