Economic evaluation of computed radiography comparing to film method in quality control of general X-ray machine at Phramongkutklao Hospital.

نویسندگان

  • Supakajee Saengruang-Orn
  • Thosporn Vimolket
  • Manus Mongkolsuk
  • Somrat Lertmaharit
  • Yawana Tanapat
  • Busabong Noola
  • Kamonwan Thungsiri
  • Pirom Kamolratanakul
چکیده

OBJECTIVE To evaluate the efficiency of quality control performance for a general x-ray machine between computed radiography (CR) and film method. MATERIAL AND METHOD CR performance as a quality control method for a general x-ray machine was compared to the film method. Two raters independently analyzed the result of quality control from both methods. Economic evaluation was performed by cost-minimization analysis. All data (result for quality control and cost) were collected from Phramongkutklao Hospital from August 2007 to January 2008. RESULT Quality control performances of a general x-ray machine by using CR and film method were equivalent. Interobserver agreement for analysis of quality control measurements was almost perfect. Unit cost, test performance time, radiation dose for quality control by CR were less than the film method (p < 0.001). CONCLUSION The performances of quality control of a general x-ray machine done by the CR method are more efficient than the film method. Using the CR method for quality control performance of the general x-ray machines will save cost enormously.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography

Introduction Blue light is a part of the spectrum with the highest energy content, which can reach the retina. The damage that it can cause to the retina is called photochemical or blue-light retinal injury. For the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (W.m-2.sr-1) seems to be...

متن کامل

Efficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography

Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were perfo...

متن کامل

The Evaluation of Conventional X-ray Exposure Parameters Including Tube Voltage and Exposure Time in Private and Governmental Hospitals of Lorestan Province, Iran

Introduction In radiography, dose and image quality are dependent on radiographic parameters. The problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. Therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation do...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

Quality Control of Radiography Equipments in Golestan Province of IRAN

Introduction The main goal of this study was to perform quality control test on all radiography units operating in Golestan province of IRAN. Materials and Methods Forty-four X-ray units were examined based on general accepted programs for quality control. Eight parameters including kVp accuracy, kVp reproducibility, mA-time reciprocity, exposure linearity, exposure reproducibility, timer accur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Medical Association of Thailand = Chotmaihet thangphaet

دوره 92 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2009