Improving cardiopulmonary bypass: does continuous blood gas monitoring have a role to play?

نویسندگان

  • Jane Ottens
  • Sigrid C Tuble
  • Andrew J Sanderson
  • John L Knight
  • Robert A Baker
چکیده

The CDI 500 (Terumo Cardiovascular Systems, Ann Arbor, MI) is an in-line blood gas monitoring device that has been used in clinical practice for over a decade. Few randomized studies have evaluated the value of this device with respect to improved perfusion management. We routinely use automated continuous quality indicator programs to assess perfusion management. The aim of this study is to investigate in a prospective randomized trial the role of in-line blood gas monitoring in the improvement of blood gas management during cardiopulmonary bypass (CPB) utilizing continuous quality indicators. Patients were randomized into two groups (Control, CDI). Patients in the Control group received our standard CPB blood gas management, with intermittent blood gas results. Continuous blood gas measurements from the CDI 500 were recorded at 20-second intervals, with the perfusionist blinded to these measurements. Patients in the CDI group received standard CPB blood gas management, in addition to continuous blood gas measurements visible on the CDI 500, the alarm system activated, and the data recorded. Perfusion management for all cases was guided by institutional protocols. One hundred patients (50 in each group) were included in the study. No significant difference existed between the groups on demographic, surgical, or clinical outcomes. Blood gas levels of patients in the CDI group were able to be maintained in accordance to protocol a greater percentage of the time, e.g., pCO2 management was 2% versus 20% (p = .008); this was most notable for differences between the Control and the CDI group for pCO2 > 45 mmHg (p = .003). Practice variation determined via statistical control charts improved for both pH and pCO2, represented by a decrease in the variation associated with practice. Continuous blood gas monitoring with the CDI 500 results in significantly improved blood gas management as determined by adherence to institutional protocols.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standards of care in perfusion: should not continuous in-line blood gas monitoring be one?

What is a standard of care? Who defines standard of care? And when does new technology, such as continuous in-line blood gas monitoring (CILBGM), become a standard of care? Perhaps the most productive and practical way to view standards of care in perfusion is as, "the best perfusion management we can provide for our patients within reason and affordability." Today, CILBGM offers a tangible pat...

متن کامل

Continuous intra-jugular venous blood-gas monitoring with the Paratrend 7 during hypothermic cardiopulmonary bypass.

We measured the accuracy of the continuous intra-vascular blood-gas monitoring system (Paratrend 7, PT7) placed in the jugular venous bulb in 18 adult patients having cardiac or aortic surgery with hypothermic cardiopulmonary bypass (CPB). After induction of anaesthesia, a PT7 sensor was inserted through a 20-gauge venous catheter into the right jugular venous bulb. Blood samples were drawn fro...

متن کامل

The effects of continuous blood gas monitoring during cardiopulmonary bypass: a prospective, randomized study--Part I.

The use of continuous in-line blood gas management (CILBGM) is steeped in controversy concerning its potential utility and impact on patient outcomes. The purpose of this study was to determine whether the use of CILBGM results in improved quality of patient care. Fifty-nine patients were enrolled in a Institutional Review Board-approved, prospective, randomized study. An in-line blood gas moni...

متن کامل

SCIENTIFIC PRESENTATION AWARD Clinical Accuracy of Continuous Hemoglobin Oxygen Saturation Monitoring Devices

-----------------Three devices used to measure hemoglobin oxygen saturation in the extracorporeal circuit were studied and compared to a control. The Baxter Bentley OxySat, Oximetrix Accusat, and the Radiometer ABL4 blood gas monitor were compared to a control, the IL 282 CoOximeter. Fifty one sample points were obtained during all phases of cardiopulmonary bypass with results as follows: TABLE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 42 3  شماره 

صفحات  -

تاریخ انتشار 2010