Some Personal Remarks on the Radon Transform

نویسندگان

  • Sigurdur Helgason
  • SIGURDUR HELGASON
چکیده

Back in 1955, I worked on extending the mean value theorem of Leifur Ásgeirsson [1937] for the ultrahyperbolic equation on Rn ×Rn to Riemannian homogeneous spaces G/K ×G/K. I was motivated by Godement’s generalization [1952] of the mean value theorem for Laplace’s equation Lu = 0 to the system Du = 0 for all G-invariant differential operators D (annihilating the constants) on G/K. At the time (Spring 1955) I visited Leifur in New Rochelle where he was living in the house of Fritz John (then on leave from NYU). They had both been students of Courant in Göttingen in the 1930’s. Since John’s book [1955] treats Ásgeirsson’s theorem in some detail, Leifur lent me a copy of it (in page proofs) to look through on the train to Boston. I was quickly enticed by Radon’s formulas (in John’s formulation) for a function f on Rn in terms of its integrals over hyperplanes. In John’s notation, let J(ω, p) denote the integral of f over the hyperplane

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Remarks on the general Funk-Radon transform and thermoacoustic tomography

The generalized Funk transform is a integral transform acting from densities on a manifold X to functions defined on a family Σ of hypersurfaces in X. The dual operator M is again a Funk transform which is defined for densities on the manifold Σ. We state twoside estimates for the operator M and a description of the range of the Funk transform operatorM and approximation theorem for the kernel ...

متن کامل

The X-ray Transform and its Application in Nano Crystallography

In this article a review on the definition of the X- ray transform and some ofits applications in Nano crystallography is presented. We shall show that the X- raytransform is a special case of the Radon transform on homogeneous spaces when thetopological group E(n)- the Euclidean group - acts on ℝ2 transitively. First someproperties of the Radon transform are investigated then the relationship ...

متن کامل

Carboxen – 564 a New Carbon Molecular Sieve Sorbent Used for Radon and Thoron Monitoring

The possibility to combine the track-etched CR-39 or Makrofol detectors with charcoal to increase the detector sensitivity was shown in the last years. Special requests are necessary in the case of a personal dosimeter when the detector must be active only during working activity. Regarding the combination of charcoal with TL detectors our preliminary investigations indicate that the TLD intens...

متن کامل

Analysis of Mojette Transform Implementation on Field Programmable Gate Array

In the last ten years there were intensive researches to find new methods for image processing. One of these methods is the Mojette transform (MOT). This transform is an exact discrete Radon transform defined for a set of specific projections. The MOT is used mainly in image processing applications. There were several implementation using personal computers [8] and [9]. There are some applicati...

متن کامل

Detection of Blood Vessels in Color Fundus Images using a Local Radon Transform

Introduction: This paper addresses a method for automatic detection of blood vessels in color fundus images which utilizes two main tools: image partitioning and local Radon transform. Material and Methods: The input images are firstly divided into overlapping windows and then the Radon transform is applied to each. The maximum of the Radon transform in each window corresponds to the probable a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013