Inter-Rater Agreement in the Assessment of Video Recordings of Eye Drop Instillation by Glaucoma Patients

نویسندگان

  • Meghan S. Park
  • Marguerite M. Patel
  • Daniel Sarezky
  • Carin Rojas
  • Clara Choo
  • Michael Choi
  • Dachao Liu
  • Alfred W. Rademaker
  • Angelo P. Tanna
  • Fabio Rapallo
چکیده

PURPOSE To create a standardized method for evaluating the video recordings of patients self-instilling eye drops and to determine the level of agreement of eye drop instillation efficacy, safety and efficiency ratings by three masked graders. DESIGN Prospective cross-sectional study. PARTICIPANTS 78 patients with open-angle glaucoma or ocular hypertension who had at least 6 months of experience with the use of eye drop medications. METHODS Participants were video recorded while self-instilling artificial tears sequentially to both eyes. Three masked observers graded these video recordings on three criteria: efficacy (the determination of whether an eye drop was instilled on the ocular surface), safety (assessment of whether the tip of the medication bottle made contact with the ocular surface or eyelids), and efficiency (the number of eye drops expressed from the bottle). MAIN OUTCOME MEASURES After grading the video recordings based on efficacy, safety, and efficiency, kappa statistics were used to estimate inter-rater agreement. RESULTS The mean kappa level of agreement for efficacy, safety, and efficiency was 0.64 (95% confidence interval (CI), 0.42-0.87), 0.73 (95% CI, 0.58-0.88), and 0.62 (95% CI, 0.42-0.81), respectively. CONCLUSIONS We demonstrated good inter-rater reproducibility of the masked analysis of video recordings of patients self-instilling eye drops based on three criteria: efficiency, safety, and efficacy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Videographic Assessment of Glaucoma Drop Instillation

PURPOSE To assess the effect of patient education on videotaped topical instillation of artificial tear drops on subsequent topical instillation. MATERIALS AND METHODS Forty-five patients, who had been using glaucoma drops for at least 6 months and with a best-corrected visual acuity of 20/100 or better, were studied. The patients were asked to instill an artificial tear drop using their accu...

متن کامل

Factors affecting eye drop instillation in glaucoma patients with visual field defect

BACKGROUND To investigate the success rate of eye drop instillation in glaucoma patients with visual field defect as well as non-glaucoma volunteers. Factors that may affect the success rate of eye drop instillation were also evaluated. DESIGN A prospective, observational study. PARTICIPANTS Seventy-eight glaucoma patients and 85 non-glaucoma volunteers were recruited in this study. METHO...

متن کامل

Test-Retest and Inter-Rater Reliability Study of the Schedule for Oral-Motor Assessment in Persian Children

Objectives: Reliable and valid clinical tools to screen, diagnose, and describe eating functions and dysphagia in children are highly warranted. Today most specialists are aware of the role of assessment scales in the treatment of affected individuals. However, the problem is that the clinical tools used might be nonstandard, and worldwide, there is no integrated assessment performed to assess ...

متن کامل

Functional Movement Screen in Elite Boy Basketball Players: A Reliability Study

Purpose: To investigate the reliability of Functional Movement Screen (FMS) in basketball players. A few studies have compared the reliability of FMS between raters with different experience in athletes. The purpose of this study was to compare the FMS scoring between the beginners and expert raters using video records.  Methods: This is a cross-sectional study. The study subjects compris...

متن کامل

Comparison of critical care nurses' clinical competency using self-assessment method and assessment by head nurses, Zanjan 2014

Background and Objectives: The high clinical competency of Critical Care Nurses (CCNs) is required, as the quality of nursing care in critical care units (CCUs) with critically ill patients is extremely important. This study was conducted to compare CCNs' clinical competency using self-assessment method and assessment by their Head nurses. Materials and Methods: This cross-sectional study wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016