Verification of dose calculation algorithms in a multi-layer heterogeneous phantom using films.
نویسندگان
چکیده
UNLABELLED The development of advanced radiation treatment techniques such as intensity modulated radiation therapy (IMRT) and volumetric intensity modulated arc therapy (VMAT) require more accurate dose calculation algorithms within the treatment planning systems (TPS) considering that the human body is composed of tissues of widely differing radiological properties and the characteristics of a therapeutic radiation treatment beam along a heterogeneous path will be different. The objective of this study was to evaluate the accuracy of 2D-isodose distributions predicted by pencil beam convolution algorithm (PBC) and anisotropic analytic algorithm (AAA) in a heterogeneous slab phantom composed of media equivalent to air, water and bone density. The measurements were done by using the films at multiple depths in the phantom for open field sizes 5 × 5 cm2 and 10 × 10 cm2. The results from this study indicated that the AAA had better agreement with the measurement compared to PBC for both the test field sizes at all selected depths; however, the limitation of AAA in predicting doses within and beyond low-density medium was observed, especially for a smaller field size (up to 32.7% and 34.0% for AAA and PBC, respectively). Furthermore, discrepancies up to -4.8% for AAA and -14.6% for PBC was seen in the high-density medium as well. Dose prediction errors by the AAA and PBC were more pronounced for a smaller test field size, especially in the low-density medium. KEYWORDS IMRT, dose calculation algorithms, Anisotropic Analytical Algorithm (AAA), Pencil Beam Convolution (PBC), Varian's Eclipse treatment planning system.
منابع مشابه
Point Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms
Background: Nowadays, advanced radiotherapy equipment includes algorithms to calculate dose. The verification of the calculated doses is important to achieve accurate results. Mostly homogeneous dosimetric phantoms are available commercially which do not mimic the actual patient anatomy; therefore, an indigenous heterogeneous pelvic phantom mimicking actual human pelvic region has been used to ...
متن کاملEvaluation of Dose Calculation Algorithms Accuracy for Eclipse, PCRT3D, and Monaco Treatment Planning Systems Using IAEA TPS commissioning tests in a Heterogeneous Phantom
Introduction: The accuracy of dose calculation algorithm (DCA) is highly considered in the radiotherapy sequences. This study aims at assessing the accuracy of five dose calculation algorithms in tissue inhomogeneity corrections, based on the International Atomic Energy Agency TEC-DOC 1583. Material and Methods: A heterogeneous phantom was sc...
متن کاملExperimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculations in heterogeneous media
IMRT often requires delivering small fields which may suffer from electronic disequilibrium effects. The presence of heterogeneities, particularly low-density tissues in patients, complicates such situations. In this study, we report on verification of the DPM MC code for IMRT treatment planning in heterogeneous media, using a previously developed model of the Varian 120-leaf MLC. The purpose o...
متن کاملThe use of EBT3 film and Delta4 for the dosimetric verification of EclipseTM treatment planning system in a heterogeneous chest phantom: an IMRT technique
Background: This study aimed to evaluate the dose calculation accuracy of EclipseTM treatment planning system (TPS) in a heterogeneous chest phantom with the intensity modulated radiotherapy (IMRT) technique using EBT3 film and Delta4. Materials and Methods: Two IMRT plans (A and B) were prepared for radiotherapy of the heterogeneous chest phantom. Plan A was between the left lung and the surro...
متن کاملA novel phantom design for brachytherapy quality assurance
Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Gulf journal of oncology
دوره 1 14 شماره
صفحات -
تاریخ انتشار 2013