Cemented Polyethylene Cups in Patients Younger Than 40 Years

نویسندگان

  • Daniël C. J. de Kam
  • Jean W. M. Gardeniers
  • Jan C. M. Hendriks
  • René P. H. Veth
  • B. Willem Schreurs
چکیده

UNLABELLED Although uncemented cup implants frequently are used in young patients, we believe long-term survival rates of cups in these patients are somewhat disappointing, and therefore we have continued to use cemented cups in primary THA, even in young patients. However, in cases of acetabular bone stock defects, we also use bone impaction grafting. We prospectively followed 130 patients with 175 cemented cups; no patients were lost to followup. The mean age of the patients at surgery was 31 years (range, 16-39 years). An acetabular reconstruction with bone impaction grafting was performed in 84 hips (48%). The minimum followup was 2 years (average, 8.1 years; range, 2.0-18.5 years). Twenty-one of the 175 cups (12%) were revised at an average of 8.1 years (range, 2.0-18.5 years). Reasons for revision were infection (one early, seven late), recurrent dislocations (two), traumatic loosening (one), and aseptic loosening (10). The 10-year survival rate of all cemented cups with end point of revision for any cause was 85%. Survival with end point of aseptic loosening of all cups was 92%. Survival with end point of revision for aseptic loosening was 90% for the cups without impaction grafting and 95% for the cups with impaction grafting. We believe cemented acetabular cups in young patients have acceptable midterm survival; however, in the case of acetabular bone defects, we recommend reconstruction with impaction grafting. LEVEL OF EVIDENCE Level III, therapeutic study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total hip arthroplasty in patients less than 40 years old with avascular necrosis of the femoral head. A 5 to 19-year follow-up study.

We evaluated 34 total hip arthroplasties (THA) for avascular necrosis of the femoral head in 26 patients who were younger than 40 years at the time of the index operation. The average age at the time of THA was 283 (17-38) years. The mean follow-up was 10.9 (5-19) years. We used 6 cemented and 28 cementless acetabular components and a cemented polished tapered stem in all hips. The mean Charnle...

متن کامل

A comparison of polyethylene wear rates between cemented and cementless cups. A prospective, randomised trial.

We selected randomly a consecutive series of 162 patients requiring hip replacement to receive either a cementless, hemispherical, modular, titanium acetabular cup or a cemented, all-polyethylene cup. These replacements were performed by two surgeons in four general hospitals. The same surgical technique was used and a 26 mm metal-head femoral component was used in every case. After exclusions,...

متن کامل

Results of 3,668 primary total hip replacements

BACKGROUND AND PURPOSE In a previous study based on the Finnish Arthroplasty Register, the survival of cementless stems was better than that of cemented stems in younger patients. However, the survival of cementless cups was poor due to osteolysis. In the present study, we analyzed population-based survival rates of the cemented and cementless total hip replacements in patients under the age of...

متن کامل

Single-stage bilateral total hip arthroplasty in patients less than 35 years. Forty arthroplasties with 5-17 years follow-up.

Between 1991 and 2003, the senior author performed 42 bilateral total hip arthroplasties as a single-stage procedure in 21 patients less than 35 years old. One patient was lost to follow-up, leaving 40 total hip arthroplasties in 11 male and 9 female patients for review, with a mean follow-up of 9.7 years (5-17 years). The mean age at the index operation was 25.2 years (range 17 to 34 years). T...

متن کامل

Polyethylene wear in uncemented acetabular components.

We measured polyethylene wear in 231 porous-coated uncemented acetabular cups. We divided the hips into two groups according to the fixation of the femoral component, by cementing (n = 97) or press-fit (n = 134). Follow-up was from three to five years. The patients in two sub-groups were matched for weight, diagnosis, sex, age and length of follow-up. The linear wear rate of cups articulated wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical Orthopaedics and Related Research

دوره 467  شماره 

صفحات  -

تاریخ انتشار 2009