Interference of serum indices in the analyzer function
نویسندگان
چکیده
Background: Analyzer has the capability to detect hemolysis, icterus, and lipemia in samples and produces semi quantitative unit less index values for hemoglobin, bilirubin, or intralipid (so-called serum indices), but these serum index functions are not intended for diagnostic purposes. With increasing amounts of the specific interfering compounds, increasing index values are generated, which are linearly correlated with the amount of interferent. Aim of our study is to find the influence of serum indices on the functioning of the analyzer. Methodology: Blood glucose estimation was done for twenty samples. Serum indices analysis was done for the same set of samples along with glucose in the next run. Time taken for analysis was noted. Results: The time taken for the estimation of glucose by automated chemistry analyzer is 9.27 minutes. When analyzed with serum indices, time required is 9.45 min. Conclusion: We have proved that there is an increase in the turnaround time when serum indices was analyzed along with glucose. However increase of 1.94% is acceptable when compared to interfering compounds influencing patients’ reports.
منابع مشابه
Positive interference in Radioimmunoassay determination of serum total T3
Introduction: Determination of thyrotropin, total and free thyroxine and triiodothyronine are widely used as diagnostic methods for thyroid function evaluation. There have been numerous reports of interferences in thyroid hormone immunoassays. Herein, a prominent positive interference is reported for a radioimmunoassay kit of total triiodothyronine. Materials and Methods: In this study, a total...
متن کاملEffects of 1:1 Mixture of Anogeissus leiocarpus and Terminalia avicennioides Root Bark Extracts on Haematological Parameters, Liver and Kidney Function Indices of Male Rats
Background: This study evaluated the effects of 1:1 mixture of aqueous root bark extracts of Anogeissus leiocarpus (DC) Guill & Perr (Combretaceae) and Terminalia avicennioides Guill & Perr (Combretaceae) in male rats. Methods: Male rats were orally administered a 1:1 mixture of both extracts (250, 500 and 1000 mg/kg body weight) for seven days. Liver and kidney function indices, haematologica...
متن کاملاثرات آلومینیوم بر غلظت آنزیمهای ALT,AST,LDH
The effect of aluminium on serum parameters related to liver function was investigated over different period of times. Serum lactate Dehydrogenase (LDH), Aspartate aminotransferase (AST), Alanin aminotransferase (ALT) and total protein were chosen as indexes for liver function. Daily intraperitoneal administration of 185 umoleslkg aluminium for 35 days elevated serum aluminium concentration f...
متن کاملEffects of Aqueous Stem Extract of Massularia Acuminata on Some Liver Function Indices of Male Rats
Background: Massularia acuminata has been claimed to be used in managing several ailments in folk medicine and in some instances substantiated with scientific data. This however has been without recourse to its safety. Therefore, aqueous stem extract of M. acuminata was evaluated for its effects on some function indices of the liver of male rats. Methods: Sixty, male rats were grouped into 4 ...
متن کاملComparison of Diagnostic Value of Cast Analyzer X Iranian Software versus Curve Expert Software for Arch Form Construction based on Mathematical Models
Objective: For the assessment of primary arch form, different methods have been used including qualitative classifications, inter-canine and inter-molar widths and quantitative and numerical methods using mathematical models. The purpose of this study was to compare the validity and reliability of Cast Analyzer X Iranian software with those of Curve Expert Professional version 1.1 for arch fo...
متن کامل