Outcome of patients with low-gradient "severe" aortic stenosis and preserved ejection fraction.

نویسندگان

  • Nikolaus Jander
  • Jan Minners
  • Ingar Holme
  • Eva Gerdts
  • Kurt Boman
  • Philippe Brudi
  • John B Chambers
  • Kenneth Egstrup
  • Y Antero Kesäniemi
  • William Malbecq
  • Christoph A Nienaber
  • Simon Ray
  • Anne Rossebø
  • Terje R Pedersen
  • Terje Skjærpe
  • Ronnie Willenheimer
  • Kristian Wachtell
  • Franz-Josef Neumann
  • Christa Gohlke-Bärwolf
چکیده

BACKGROUND Retrospective studies have suggested that patients with a low transvalvular gradient in the presence of an aortic valve area < 1.0 cm² and normal ejection fraction may represent a subgroup with an advanced stage of aortic valve disease, reduced stroke volume, and poor prognosis requiring early surgery. We therefore evaluated the outcome of patients with low-gradient "severe" stenosis (defined as aortic valve area < 1.0 cm² and mean gradient ≤ 40 mm Hg) in the prospective Simvastatin and Ezetimibe in Aortic Stenosis (SEAS) study. METHODS AND RESULTS Outcome in patients with low-gradient "severe" aortic stenosis was compared with outcome in patients with moderate stenosis (aortic valve area 1.0 to 1.5 cm²; mean gradient 25 to 40 mm Hg). The primary end point of aortic valve events included death from cardiovascular causes, aortic valve replacement, and heart failure due to aortic stenosis. Secondary end points were major cardiovascular events and cardiovascular death. In 1525 asymptomatic patients (mean age, 67 ± 10 years; ejection fraction, ≥ 55%), baseline echocardiography revealed low-gradient severe stenosis in 435 patients (29%) and moderate stenosis in 184 (12%). Left ventricular mass was lower in patients with low-gradient severe stenosis than in those with moderate stenosis (182 ± 64 versus 212 ± 68 g; P < 0.01). During 46 months of follow-up, aortic valve events occurred in 48.5% versus 44.6%, respectively (P = 0.37; major cardiovascular events, 50.9% versus 48.5%, P = 0.58; cardiovascular death, 7.8% versus 4.9%, P = 0.19). Low-gradient severe stenosis patients with reduced stroke volume index (≤ 35 mL/m²; n = 223) had aortic valve events comparable to those in patients with normal stroke volume index (46.2% versus 50.9%; P = 0.53). CONCLUSIONS Patients with low-gradient "severe" aortic stenosis and normal ejection fraction have an outcome similar to that in patients with moderate stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bicuspid aortic valve stenosis with successful transfemoral transcatheter aortic valve replacement (TAVI) using the Sapien 3 valve.

catheterization study. Circulation 2013;128:S235–S242. 18. Dumesnil JG, Pibarot P. Letter by Dumesnil and Pibarot regarding article, ‘Outcome of patients with low-gradient ‘severe’ aortic stenosis and preserved ejection fraction’. Circulation 2011;124:e360. 19. Cueff C, Serfaty JM, Cimadevilla C, Laissy JP, Himbert D, Tubach F, Duval X, Iung B, Enriquez-Sarano M, Vahanian A, Messika-Zeitoun D. ...

متن کامل

Impact of aortic valve replacement on outcome of symptomatic patients with severe aortic stenosis with low gradient and preserved left ventricular ejection fraction.

BACKGROUND The optimal management of low-gradient "severe" aortic stenosis (mean gradient <40 mm Hg, indexed aortic valve area ≤0.6 cm2/m2) with preserved left ventricular ejection fraction remains controversial because gradients may be similar after aortic valve replacement (AVR). We compared outcomes of low-gradient severe aortic stenosis with AVR or medical therapy. METHODS AND RESULTS Com...

متن کامل

Response to letters regarding article, "systemic hypertension in low-gradient severe aortic stenosis with preserved ejection fraction".

BACKGROUND Low-gradient severe aortic stenosis with preserved ejection fraction is an increasingly recognized entity, and symptomatic patients may benefit from aortic valve replacement. However, systemic hypertension frequently coexists with low-gradient severe aortic stenosis, which itself may cause elevated left ventricular (LV) filling pressures with resultant symptoms of dyspnea. METHODS ...

متن کامل

Outcome of patients with aortic stenosis, small valve area, and low-flow, low-gradient despite preserved left ventricular ejection fraction.

OBJECTIVES The aim of this case match study was to compare the outcome of patients with paradoxical low-flow (left ventricular ejection fraction [LVEF] ≥50% but stroke volume index <35 ml/m(2)), low-gradient (mean gradient [MG] <40 mm Hg), a priori severe (aortic valve area [AVA] ≤1.0 cm(2)) aortic stenosis (AS) (PLG-SAS group) with that of patients with a severe AS (AVA ≤1.0 cm(2)) and consist...

متن کامل

Severe aortic valve stenosis with low-gradient and preserved ejection fraction: a misclassification issue?

INTRODUCTION AND OBJECTIVES Low-gradient severe aortic stenosis with preserved ejection fraction is a controversial entity. Misclassification of valvulopathy severity could explain the inconsistencies reported in the prognosis of these patients. Planimetry of the aortic area using three-dimensional transesophageal echocardiography could clear up these doubts. The objectives were to assess the a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 123 8  شماره 

صفحات  -

تاریخ انتشار 2011