Progressive loss in circulating volume during haemodialysis can be monitored by time voltage integral area of QRS complex: pilot study
نویسندگان
چکیده
INTRODUCTION Time voltage area of QRS is a parameter that showed a close association with modifications in endoventricular volume. The aim of the study was to investigate the efficacy of this parameter in identifying progressive reduction in circulating blood volume (BV) during haemodialytic treatment (HT). MATERIAL AND METHODS Thirteen uraemic patients were studied. XYX like leads were monitored before, during and after HT. Summation of areas of each QRS complex was named QRS total area (TA). RESULTS Increase in QRS TA and decrease in BV were found after vs. before HT. Progressive increase in QRS TA is strongly linked to a progressive reduction of BV during HT. CONCLUSIONS THESE FINDINGS ENCOURAGE USE OF ECG MONITORING DURING HT WITH A DUAL PURPOSE: rhythm and haemodynamic control. In fact, excessive or insufficient subtractions of water, with consequent hypotensive or cardiorespiratory crisis, are the most frequent complications in these patients.
منابع مشابه
Time-voltage QRS area of the 12-lead electrocardiogram: detection of left ventricular hypertrophy.
Identification of left ventricular hypertrophy (LVH) using 12-lead ECG criteria based primarily on QRS amplitudes has been limited by poor sensitivity at acceptable levels of specificity. Because the product of QRS voltage and duration, as an approximation of the time-voltage area of the QRS complex, can improve accuracy of the 12-lead ECG for LVH, we examined the diagnostic value of true time-...
متن کاملAnalysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype
One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...
متن کاملAnalysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype
One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...
متن کاملStudy of Variation of the J-integral and the Fracture Toughness in Blunt V-notches under Mode I Loading
Fracture assessment of U- and V-notches is important in mechanical engineering. One can use the J-integral as fracture parameter in order to predict the critical fracture load in notches. The critical value of the J-integral in cracks is a function of the material properties. In notches, however, the material properties as well as the notch dimensions affect this critical value (named fracture ...
متن کاملAn Intelligent Method Based on WNN for Estimating Voltage Harmonic Waveforms of Non-monitored Sensitive Loads in Distribution Network
An intelligent method based on wavelet neural network (WNN) is presented in this study to estimate voltage harmonic distortion waveforms at a non-monitored sensitive load. Voltage harmonics are considered as the main type of waveform distortion in the power quality approach. To detect and analyze voltage harmonics, it is not economical to install power quality monitors (PQMs) at all buses. The ...
متن کامل