Hyperspectral X-ray imaging for scatter removal in mammography

نویسندگان

  • Silvia PANI
  • James Scuffham
چکیده

The purpose of this study is to investigate the use of hyperspectral X-ray imaging i.e, an imaging modality where spectral information on detected X-rays is available, for the removal of scatter in mammography. Features that suggest the presence of cancer are often low in contrast or small in size and therefore a good image quality is required in order to locate them. Current mammography systems use an anti-scatter grid to remove scatter from the image. However, this device also absorbs a proportion of the primary beam and therefore a rise in the dose is required in order to compensate for the loss in statistics. Two alternative methods of scatter removal were investigated in this study. Compton scattered X-rays lose energy in the scattering process and therefore appear at a lower energy in the detected spectrum. Imaging using a monochromatic X-ray beam and a spectroscopic detector means that these lower energy scattered X-rays can be removed from the image through spectral windowing. An alternative method of removing scatter is to simulate the scatter using Monte Carlo modelling. Once a scatter spectrum has been obtained using an input spectrum similar to the experimental spectrum it can be subtracted from the detected spectrum, creating a scatter-free image. This work presents imaging work carried out with a pixellated spectroscopic CdTe detector. A first approach involved the use of a mosaic crystal monochromator producing a quasimonochromatic spectrum from which the scattered component can be removed. The second approach involved the subtraction of the scattered spectrum, as obtained from Monte-Carlo modelling, from a full polychromatic spectrum. Both approaches were tested on a customdesigned low contrast test object. Results showed that in the monochromatic approach scatter removal gave a 40% increase in contrast. It was also found that removing scatter using a simulated scatter spectrum and a polychromatic beam produced a contrast improvement of around 15% when compared to full spectrum imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography).

A theoretical method is presented that allows identification of optimal x-ray imaging geometry, considering the effects of x-ray source distribution, imaging task, x-ray scatter, and imager detective quantum efficiency (DQE). Each of these factors is incorporated into the ICRU-recommended figure of merit for image quality, the detectability index, which is maximized to determine the optimal sys...

متن کامل

Scatter correction in digital mammography based on image deconvolution.

X-ray scatter is a major cause of nonlinearity in densitometry measurements using digital mammography. Previous scatter correction techniques have primarily used a single scatter point spread function to estimate x-ray scatter. In this study, a new algorithm to correct x-ray scatter based on image convolution was implemented using a spatially variant scatter point spread function which is energ...

متن کامل

A Novel Approach to Scatter-free Imaging for the Improvement of Breast Cancer Detection

Compton scattering is one of the main causes of image degradation in X-ray imaging. This is particularly noticeable in mammography where details of interest feature low contrast in comparison to the surrounding tissue. This work shows the feasibility of obtaining scatter-free images by using a quasimonochromatic X-ray beam and a pixellated spectroscopic detector. This work presents characterisa...

متن کامل

بررسی ارزش تشخیصی اسکن 99mTc-MIBI (Scintimammography) در بدخیمی های پستان

The breast cancer is common in females.Early detection with safe , convenient , noninvasive and accessible diagnostic tools are important. X- ray mammography is still the first choice imaging for breast cancer, but has low specificity and limited value in dense breast and surgically scarred breasts. In recent years , MIBI scintimammography has been used for this purpose. The...

متن کامل

Digital Mammography with a Mosaic of Ccd Arrays

A digital mammography device uses a mosaic of electronic digital imaging arrays to scan an x-ray image. The mosaic of arrays is repositioned several times to expose different portions of the image, until the entire image is scanned. The data generated by the arrays during each exposure is stored in a computer. After the final exposure, the computer combines data of the several partial images to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016