Invasive arterial BP monitoring in trauma and critical care: effect of variable transducer level, catheter access, and patient position.

نویسندگان

  • U G McCann
  • H J Schiller
  • D E Carney
  • J Kilpatrick
  • L A Gatto
  • A M Paskanik
  • G F Nieman
چکیده

OBJECTIVES (1) To determine the validity of current recommendations for direct arterial BP measurement that suggest that the transducer (zeroed to atmosphere) be placed level with the catheter access regardless of subject positioning: and (2) to investigate the effect of transducer level, catheter access site, and subject positioning on direct arterial BP measurement. DESIGN Prospective, controlled laboratory study. SETTING Large animal laboratory. SUBJECTS Five Yorkshire pigs. INTERVENTIONS Anesthetized animals had 16F catheters placed at three access sites: aortic root, femoral artery, and distal hind limb. Animals were placed in supine, reverse Trendelenburg 35 degrees, and Trendelenburg 25 degrees positions with a transducer placed level to each access site while in every position. MEASUREMENTS AND MAIN RESULTS For each transducer level, five systolic and diastolic pressures were measured and used to calculate five corresponding mean arterial pressures (MAPs) at each access site. When transducers were at the aortic root, MAP corresponding to aortic root pressure was obtained in all positions regardless of catheter access site. When transducers were moved to the level of catheter access, as current recommendations suggest, significant errors in aortic MAP occurred in the reverse Trendelenburg position. The same trend for error was noted in the Trendelenburg position but did not reach statistical significance. CONCLUSIONS (1) Current recommendations that suggest placing the transducer at the level of catheter access regardless of patient position are invalid. Significant errors occur when subjects are in nonsupine positions. (2) Valid determination of direct arterial BP is dependent only on transducer placement at the level of the aortic root, and independent of catheter access site and patient position.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients

Few studies assessed modalities of invasive arterial pressure monitoring (IAPM). We evaluated effects on measured values of various combinations of transducer level, catheter access site, and patient position. Prospective observational study in consecutive adults admitted to a French intensive care unit in 2009 to 2011 and fulfilling our inclusion criteria. Four combinations (B-E) of transducer...

متن کامل

The relationship between arterial transducer level and pulse contour waveform-derived measurements

For hemodynamic monitoring, the pressure transducer is suggested to be fixed at the level of the phlebostatic axis in critically ill patients [1,2]. The correction and adjustment of pressure transducer are emphasized in central venous pressure monitoring in clinical practice. The exact position of the transducer is relatively easy to be ignored for invasive arterial blood pressure monitoring [3...

متن کامل

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Cardiac Output Monitoring by Pulse Contour Analysis, the Technical Basics of Less-Invasive Techniques

Routine use of cardiac output (CO) monitoring became available with the introduction of the pulmonary artery catheter into clinical practice. Since then, several systems have been developed that allow for a less-invasive CO monitoring. The so-called "non-calibrated pulse contour systems" (PCS) estimate CO based on pulse contour analysis of the arterial waveform, as determined by means of an art...

متن کامل

تخمین فشار متوسط شریانی توسط پایش تهاجمی فشار شریانی با مانومتر

Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 120 4  شماره 

صفحات  -

تاریخ انتشار 2001