Intensity Modulated Radiotherapy Using Multiple in Fields Compared to Wedged Fields in Breast Irradiation: Clinical Impact on Early Skin Reaction and Organs at Risk Doses

نویسنده

  • Hala Ahmed Zaghloul
چکیده

Objective: To measure the impact of multiple field in filed (MFIF) technique on dose homogeneity, doses to organs at risk (OARs) and acute skin toxicity in comparison to physical wedged (PW) tangential technique. Methods: The study population consisted of 75 patients who had breastconserving surgery and whole-breast radiation using MFIF.These patients were matched one-to-one to a control group of 75 patients treated with PW tangents, following ethical board approval and signing informed consents. Acute skin reaction was graded by CTCAE 3.0 scoring and multiple regression analysis of covariates was performed. Results: CTCAE grade2 acute skin reaction occurred in 61.3% PW vs. 32% MFIF while grade 3 was encountered in 24% PW vs. 10.7% MFIF patients (P<0.01). Multiple regression analysis confirmed the excessive skin reaction to the related radiation therapy technique (P = 0.0002) and whole breast PTV (P < 0.001). Homogeneity index within PTV was significantly improved in MFIF plans (0.84 ± 0.7) compared with PW (0.94 ± 0.15) with a (P < 0.01). There was also a significant reduction, in lung V20 from 14.3%±1.1to 10.6% ±1.4 (P<0.01), heart V30 from 7%±5.8 to 6%±4.9 (p<0.001). Contralateral breast volume receiving dose more than 2 Gy was also reduced 2.3%±0.5 PW to 1.2%±0.2 MFIF (P<0.01). Conclusion: The MFIF technique significantly improved PTV dose homogeneity index, while significantly reduced the incidence of grade 2/3 acute skin reaction and doses to OARs when compared to PW tangential fields in whole breast radiotherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intensity-modulated radiation therapy for early-stage breast cancer: is it ready for prime time?

Whole breast external beam radiotherapy (WBEBRT) is commonly used as an essential arm in the treatment management of women with early-stage breast cancer. Dosimetry planning for conventional WBEBRT typically involves a pair of tangential fields. Advancement in radiation technology and techniques has the potential to improve treatment outcomes with clinically meaningful long-term benefits. Howev...

متن کامل

Quantification the dosimetric parameters of asymmetric physical wedged-6MV photon beam

Introduction: Physical wedge as a useful tool has been utilized in radiotherapy to modify photon beam shape and intensity such that it distributes dose uniformly in tumor site and reduces hot points. Since during Linac commissioning dosimetric parameters like output factors and lateral dose profiles are measured only for symmetric open and wedged fields, so calculation the par...

متن کامل

Comparison of forward intensity modulated radiation therapy and two field tangential wedged beam techniques in radiotherapy of breast cancer: dosimetric and radiobiologic study

Introduction: This study aims to compare the dose delivery parameters and radiobiologic model prediction of Tumor Control Probability (TCP) of the FIMRT technique compared with rectangular two tangential wedged fields (2FW) in the treatment of breast cancer. Furthermore, reduction of the heart and lung dose in the FIMRT was studied via dosimetric parameters and radiobiologic mo...

متن کامل

Intensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields

Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...

متن کامل

Characterization of Wedge Factors and Dose Distributions in Radiotherapy with Symmetric and Asymmetric Physical Wedged Beams of 6 MV Photon Beam

Introduction: Physical wedge by modify photon beam shape and intensity has been utilized in radiotherapy to obtain uniformly dose distribution in tumor site with reduced hot spots. Calculation of dosimetric parameters for both symmetric and asymmetric wedged fields is proved necessary during linear accelerator (Linac) commissioning. The present study aimed to achieve o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015