Intensity Modulated Radiotherapy Using Multiple in Fields Compared to Wedged Fields in Breast Irradiation: Clinical Impact on Early Skin Reaction and Organs at Risk Doses
نویسنده
چکیده
Objective: To measure the impact of multiple field in filed (MFIF) technique on dose homogeneity, doses to organs at risk (OARs) and acute skin toxicity in comparison to physical wedged (PW) tangential technique. Methods: The study population consisted of 75 patients who had breastconserving surgery and whole-breast radiation using MFIF.These patients were matched one-to-one to a control group of 75 patients treated with PW tangents, following ethical board approval and signing informed consents. Acute skin reaction was graded by CTCAE 3.0 scoring and multiple regression analysis of covariates was performed. Results: CTCAE grade2 acute skin reaction occurred in 61.3% PW vs. 32% MFIF while grade 3 was encountered in 24% PW vs. 10.7% MFIF patients (P<0.01). Multiple regression analysis confirmed the excessive skin reaction to the related radiation therapy technique (P = 0.0002) and whole breast PTV (P < 0.001). Homogeneity index within PTV was significantly improved in MFIF plans (0.84 ± 0.7) compared with PW (0.94 ± 0.15) with a (P < 0.01). There was also a significant reduction, in lung V20 from 14.3%±1.1to 10.6% ±1.4 (P<0.01), heart V30 from 7%±5.8 to 6%±4.9 (p<0.001). Contralateral breast volume receiving dose more than 2 Gy was also reduced 2.3%±0.5 PW to 1.2%±0.2 MFIF (P<0.01). Conclusion: The MFIF technique significantly improved PTV dose homogeneity index, while significantly reduced the incidence of grade 2/3 acute skin reaction and doses to OARs when compared to PW tangential fields in whole breast radiotherapy.
منابع مشابه
Intensity-modulated radiation therapy for early-stage breast cancer: is it ready for prime time?
Whole breast external beam radiotherapy (WBEBRT) is commonly used as an essential arm in the treatment management of women with early-stage breast cancer. Dosimetry planning for conventional WBEBRT typically involves a pair of tangential fields. Advancement in radiation technology and techniques has the potential to improve treatment outcomes with clinically meaningful long-term benefits. Howev...
متن کاملQuantification the dosimetric parameters of asymmetric physical wedged-6MV photon beam
Introduction: Physical wedge as a useful tool has been utilized in radiotherapy to modify photon beam shape and intensity such that it distributes dose uniformly in tumor site and reduces hot points. Since during Linac commissioning dosimetric parameters like output factors and lateral dose profiles are measured only for symmetric open and wedged fields, so calculation the par...
متن کاملComparison of forward intensity modulated radiation therapy and two field tangential wedged beam techniques in radiotherapy of breast cancer: dosimetric and radiobiologic study
Introduction: This study aims to compare the dose delivery parameters and radiobiologic model prediction of Tumor Control Probability (TCP) of the FIMRT technique compared with rectangular two tangential wedged fields (2FW) in the treatment of breast cancer. Furthermore, reduction of the heart and lung dose in the FIMRT was studied via dosimetric parameters and radiobiologic mo...
متن کاملIntensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields
Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...
متن کاملCharacterization of Wedge Factors and Dose Distributions in Radiotherapy with Symmetric and Asymmetric Physical Wedged Beams of 6 MV Photon Beam
Introduction: Physical wedge by modify photon beam shape and intensity has been utilized in radiotherapy to obtain uniformly dose distribution in tumor site with reduced hot spots. Calculation of dosimetric parameters for both symmetric and asymmetric wedged fields is proved necessary during linear accelerator (Linac) commissioning. The present study aimed to achieve o...
متن کامل