Dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with high-dose-rate brachytherapy for large prostate volumes.

نویسندگان

  • George Yang
  • Tobin J Strom
  • Richard B Wilder
  • Kushagra Shrinath
  • Eric A Mellon
  • Daniel C Fernandez
  • Matthew C Biagioli
چکیده

PURPOSE To evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes. MATERIALS AND METHODS One hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL) were treated with high-dose-rate (HDR) brachytherapy ± intensity modulated radiation therapy (IMRT) to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38%) unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE) version 4. RESULTS Median follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3%) patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17%) patients developed Grade 2 acute urinary retention. American Urological Association (AUA) symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p=0.04). There was no ≥ Grade 3 acute toxicity. CONCLUSIONS Dosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

The effect of Rectal Retractor, a rectal protector on rectal dose in radical prostate radiotherapy

Introduction: The close proximity of the rectum tissue to the prostate gland results in rectal toxicity during prostate radiotherapy. Rectal Retractor (RR) is a rectal displacement technique that inserts into the rectum, as a result, the lateral and dorsal part of the rectal wall push away from high dose areas. The aim of this study was to investigate the dosimetric consequence...

متن کامل

High-dose-rate brachytherapy delivered in two fractions as monotherapy for low-risk prostate cancer

PURPOSE High-dose-rate (HDR) brachytherapy has been accepted as an effective and safe method to treat prostate cancer. The aim of this study was to describe acute toxicity following HDR brachytherapy to the prostate, and to examine the association between dosimetric parameters and urinary toxicity in low-risk prostate cancer patients. MATERIAL AND METHODS Patients with low-risk prostate cance...

متن کامل

Assessment of absorbed dose uncertainty of prostate due to source relocating in brachytherapy by monte carlo method

Brachytherapy, is a method to treat prostate cancer in which a radiation source is placed inside or next to the cancer affected tissues. Purpose of this article is to determine the uncertainty level of received dose in prostate tissue due to the relocation of the placed radiation sources and inflation in prostate after positioning the radiation seeds. To simulate the model 6711 Amersham (activi...

متن کامل

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International braz j urol : official journal of the Brazilian Society of Urology

دوره 41 3  شماره 

صفحات  -

تاریخ انتشار 2015