ROC curves in clinical chemistry: uses, misuses, and possible solutions.
نویسندگان
چکیده
BACKGROUND ROC curves have become the standard for describing and comparing the accuracy of diagnostic tests. Not surprisingly, ROC curves are used often by clinical chemists. Our aims were to observe how the accuracy of clinical laboratory diagnostic tests is assessed, compared, and reported in the literature; to identify common problems with the use of ROC curves; and to offer some possible solutions. METHODS We reviewed every original work using ROC curves and published in Clinical Chemistry in 2001 or 2002. For each article we recorded phase of the research, prospective or retrospective design, sample size, presence/absence of confidence intervals (CIs), nature of the statistical analysis, and major analysis problems. RESULTS Of 58 articles, 31% were phase I (exploratory), 50% were phase II (challenge), and 19% were phase III (advanced) studies. The studies increased in sample size from phase I to III and showed a progression in the use of prospective designs. Most phase I studies were powered to assess diagnostic tests with ROC areas >/=0.70. Thirty-eight percent of studies failed to include CIs for diagnostic test accuracy or the CIs were constructed inappropriately. Thirty-three percent of studies provided insufficient analysis for comparing diagnostic tests. Other problems included dichotomization of the gold standard scale and inappropriate analysis of the equivalence of two diagnostic tests. CONCLUSION We identify available software and make some suggestions for sample size determination, testing for equivalence in diagnostic accuracy, and alternatives to a dichotomous classification of a continuous-scale gold standard. More methodologic research is needed in areas specific to clinical chemistry.
منابع مشابه
Monoclonal versus polyclonal ELISA for assessment of fecal elastase concentration: pitfalls of a new assay.
BSJFW, et al. Automated measurement of unsaturated iron binding capacity is an effective screening strategy for C282Y homozygous hemochromatosis. Gut 2000;46:405–9. 14. Witte DL, Crosby WH, Edwards CQ, Fairbanks VF, Mitros FA. Hereditary hemochromatosis. Clin Chim Acta 1996;245:139–200. 15. Adams PC, Bhayana V. Unsaturated iron binding capacity: a screening test for hemochromatosis? Clin Chem 2...
متن کاملWhat properties should an overall measure of test performance possess?
To the Editor: Obuchowski et al. (1 ) recently reviewed the uses and misuses of ROC curves and explained, in simple terms, some sophisticated solutions to frequent problems, thereby popularizing tools described elsewhere, notably in the book coauthored by Nancy Obuchowski (2 ). What prompts me to comment on this careful and timely review are two fundamental questions: What properties should an ...
متن کاملROC curve analysis: an example showing the relationships among serum lipid and apolipoprotein concentrations in identifying patients with coronary artery disease.
Clinical accuracy, defined as the ability to discriminate between states of health, is the fundamental property of any diagnostic test or system. It is readily expressed as clinical sensitivity and specificity, and elegantly represented by the receiver operating characteristic (ROC) curve. To demonstrate the use of ROC curves, we reexamine a study of the ability of serum lipid and apolipoprotei...
متن کاملMisuse Detection in Consent-Based Networks
Consent-based networking, which requires senders to have permission to send traffic, can protect against multiple attacks on the network. Highly dynamic networks like Mobile Ad-hoc Networks (MANETs) require destination-based consent networking, where consent needs to be given to send to a destination in any path. These networks are susceptible to multipath misuses by misbehaving nodes. In this ...
متن کاملPhospholipid autoantibodies and the antiphospholipid antibody syndrome: diagnostic accuracy of 23 methods studied by variation in ROC curves with number of clinical manifestations.
BACKGROUND We analyzed the diagnostic accuracies for the diagnosis of antiphospholipid syndrome (APS) of 23 antiphospholipid antibody (APL-Ab) assays targeted at different antigen preparations and immunoglobulin isotypes. METHODS In 144 patients with suspected APS, anti-cardiolipin (aCL) and anti-beta2-glycoprotein I (abeta2GPI) antibodies were measured with 23 different ELISAs from three man...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 50 7 شماره
صفحات -
تاریخ انتشار 2004