Abstract: A Novel Text Messaging Alert System Used with Continuous Tissue Oximetry Monitoring to Improve Free Flap Outcomes

نویسندگان

  • Joseph A. Ricci
  • Christina R. Vargas
  • Adam M. Tobias
  • Samuel J. Lin
  • Amir H. Taghinia
  • Bernard T. Lee
چکیده

MethodS: 21 consecutive pediatric patients undergoing first stage autologous total ear reconstruction were retrospectively evaluated. The first 10 patients were treated traditionally (non-ICGA) and the latter 11 patients were evaluated with ICGA intraoperatively after implantation of the cartilage construct and administration of suction. Relative and absolute perfusion units in the form of contour maps were generated. Statistical analyses were performed using independent sample Student’s t test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Abstract: ATAC-seq Reveals Heterogeneity of Fibroblasts During Transition from Scarless Fetal to Scar-Forming Adult Wound Repair

MATERIALS AND METHODS: A retrospective review was performed of a prospectively collected database of all microsurgical breast reconstructions from 2008 to 2015. A novel text messaging system was introduced in 2013 and programmed to send text messages alert when the tissue oximetry readings suggested potential flap compromise based on established thresholds. Patient demographics and complication...

متن کامل

The CC-V Flap: A Novel Technique for Augmenting a C-V Nipple Reconstruction Using a Free Dermal Graft

BACKGROUND We present a novel method for augmenting the standard C-V flap used for nipple reconstruction with a free dermal graft which aims to improve the appearance of the nipple reconstruction, decrease loss of projection and improve patient satisfaction overall. METHODS The surgical technique for performing a free dermal graft augmentation of a CV flap is described. All patients who unde...

متن کامل

Noninvasive tissue oximetry for flap monitoring: an initial study.

The ideal monitoring tool to evaluate free flap success should be noninvasive, continuous, and reliable. A new device, the ViOptix Tissue Oximeter (ODISsey) based on near-infrared spectroscopy was evaluated in 30 patients undergoing autologous tissue perforator free flap breast reconstruction with continuous monitoring of the flap during elevation, transfer, and the postoperative period. The de...

متن کامل

Transcutaneous PCO2 Measurement at Low Temperature for Reliable and Continuous Free Flap Monitoring: Experimental and Clinical Study

BACKGROUND Measurement of transcutaneous oxygen pressure (TcPO2) and transcutaneous carbon dioxide pressure (TcPCO2) has been used for free flap monitoring. Because these values are obtained with sensor probes heated to 44°C, there is potential for low-temperature burns on skin flaps. We measured TcPO2 and TcPCO2 at 37°C in both animals and humans to determine the feasibility and safety of the ...

متن کامل

نتایج عمل جراحی بازسازی نقص بافتی در جراحی سرطان‌های سر و گردن به‌روش فلپ آزاد: گزارش 29 مورد

Background: Reconstruction by free tissue transfer and microvascular anastomosis can provide a reliable repair for tissue defects in head and neck surgeries. During this study, we evaluated the clinical characteristics and outcomes of reconstructive surgery by the use of free flaps for defects resulting from head and neck cancers. Methods: This quasi-experimental study included 29 patients ha...