Improved Detection Sensitivity with Combined WPT and HHT for Power Transformer Winding Deformation Analysis
نویسندگان
چکیده
The success of health monitoring and condition assessment of power transformers based on winding current signature analysis lies on proper extraction of features. The extraction of features in turn depends on appropriate signal processing methods. Fourier based signal analysis provides only frequency information and also suitable only for stationary signals. In this paper we present a combined Wavelet Packet Transform (WPT) and Hilbert Huang Transform (HHT) based time scale and time frequency analysis for the extraction of power transformer winding current features through an experimental study. The experimental work is based on short circuit test conducted on a 33 kV/11 kV, 10 MVA power transformer and axial winding deformation fault is introduced by loosening the bolts of winding structure. It is observed that Combined WPT and HHT offers better feature extraction strategy than analysis using HHT alone. Keywordstransformer, WPT, HHT, axial deformation, feature extraction, detection sensitivity 1.
منابع مشابه
Power Auto-transformer Mechanical Faults Diagnosis Using Finite Element based FRA
Frequency response analysis (FRA) is a sensitive method established for testing the mechanical integrity of transformers. However, interpretation of FRA signature still needs expert opinions and there is no FRA interpretation code generally accepted. Various mechanical faults with different extents on power transformers are required to aid FRA interpretation. To address this challenge, in...
متن کاملModal parameters identification of power transformer winding based on improved Empirical Mode Decomposition method
Modal parameters of power transformer winding are closely related to transformer manufacturing and detection technology of winding deformation based on vibration analysis method. Aimed at identifying the modal parameters of transformer winding accurately, a modal experiment is designed and made on a real 10 kV power transformer. An improved Empirical Mode Decomposition (EMD) algorithm is propos...
متن کاملA Feasible Solution to Distinguish the Transformer Winding Deformation from Insulation Characteristic Impacts on FRA Spectrum
Frequency Response Analysis (FRA) is popular technique which has been used since the last decade as a diagnostic method for transformers. However, accurate interpretation of FRA measurements is still challenging. Recent studies reveal that apart from winding deformation, FRA data can also be influenced by moisture variation in transformer paper insulation. Hence, a specific transformer’s model ...
متن کاملCharacterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...
متن کاملRecognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces
Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...