A Hybrid Diagnosis Approach on Transformer’s Insulating Oil
نویسنده
چکیده
The immersed-oil power transformer is so vital equipment in power system that maintenanceengineers take more monitor from transformer’s insulating oil to diagnose what is condition of operation. Then the dissolved gas analysis (DGA) is known for an effective technique on detecting incipient faults in oil-immersed power transformers. In this paper, a practical method is presented which consists of the Roger & Dernenber Ratio Methods, the Linear SVM diagnosis, the Key Gas method and the Specification ANSI/IEEE C57.104 Standard. Thus, incipient faults in power immersed-oil transformers can be directly identified by a report’s form which is so easy understood that we can accurate of diagnosis transformer. The user only keys in the measured data of main gases such as H2, CH4, C2H2, C2H4, C2H6, and CO those gases were must decompose via ASTMD3612. The diagnosis result was showed in texts. This paper was taken some data from Taiwan and Siemens Power Company to verify the program that was validation and accuracy of the transformer’s insulating oil diagnosis tool.
منابع مشابه
A Heuristic Approach to the Diagnosis of Transformer’s Insulating Oil
The transformer plays so important equipment in power system that engineers take more measures on the insulating oil of transformer by diagnosis. The dissolved gas analysis (DGA) is an effective technique for detecting incipient faults in oil-immersed power transformers. So the paper investigates the DGA methods, while employ the ANSI/IEEE C57.104 standards and the Key Gas diagnosis rules as ba...
متن کاملAging Assessment of Power Transformer Using Multi-parameters
As the population of transformers in service increases and their operating time extends, much attention has been focused on their availability and reliability. However, insufficient research work concentrates on how to evaluate transformer’s aging condition, although huge progress has been made on the techniques of fault diagnosis and condition assessment of transformer in past decades. This pa...
متن کاملAnalysing a power transformer’s internal response to system transients using a hybrid modelling methodology
This article presents a novel approach to analysing a power transformer’s internal response to system transients. In this approach a hybrid modelling methodology is adopted which leverages the distinct advantages offered by both Black and Grey Box modelling techniques. The Black Box model of the transformer is used within the EMTP system study environment in order to take advantage of its mathe...
متن کاملComparison of Dissolved Gases in Mineral and Vegetable Insulating Oils under Typical Electrical and Thermal Faults
Dissolved gas analysis (DGA) is attracting greater and greater interest from researchers as a fault diagnostic tool for power transformers filled with vegetable insulating oils. This paper presents experimental results of dissolved gases in insulating oils under typical electrical and thermal faults in transformers. The tests covered three types of insulating oils, including two types of vegeta...
متن کاملEstimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms
Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....