Evaluation of image quality and lens's radiation dose of a low-dose cranial CT scan.

نویسندگان

  • Pipat Chiewvit
  • Jitladda Ananwattanasuk
  • Manus Mongkolsuk
  • Chulaluk Boonma
  • Suthisak Suthipongchai
چکیده

OBJECTIVE To determine the lowest miliampere-second (mAs) of a cranial computed tomography (CT) scan that can maintain acceptable image quality on cranial CT scan which might help reducing the risk of cataract formation. MATERIAL AND METHOD The present study was performed on the 148 patients in routine daily practice sent for diagnosis of intracranial conditions by a cranial CT scan. During the cranial CT scanning, each lens's radiation dose on patient's eyes was measured by a thermoluminescent dosimeter Clinical image quality, particularly in analysis of gray and white matter differentiation, was evaluated independently using a 5 point scale by two radiologists. RESULTS During standard cranial CT scan protocol with 250 miliampere-second (mAs), the total dose of left and right lens's dose were about 50.93 miligray (mGy) and 51.66 mGy, respectively. When applying low dose cranial CT scan protocols by decreasing mAs to 200, 150 and 100 mAs, the total dose ofright and left lens were of 45.68 mGy and 46.04 mGy for 200 mAs, 34.65 mGy and 34.77 mGy for 150 mAs, 28.73 mGy and 29.25 mGy for 100 mAs respectively. CONCLUSION A low dose cranial CT scan at 100 miliampere-second provides not only an acceptable clinical image quality, but also decreases the lens's radiation dose by 43%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

Estimation of radiation dose to the lens of eyes of patients undergoing cranial computed tomography in a teaching Hospital in Osun state, Nigeria

Background: One of the means of assessing dose to patients from Computed tomography (CT) procedure is through the determination of the skin entrance dose (ESD) with the appreciation of the concern that ocular exposure effects from CT scan includes possible induction of cancer and cataract. Due to the relatively more recent introduction of CT scans, little work has been done in this area in the ...

متن کامل

Image Optimization and reduction of radiation dose in CT of the paranasal sinuses

Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...

متن کامل

Evaluation of Occupational Radiation Dose in One Year for Operators Working in CT Scan Centers

Introduction: Becuase of the most radiation dose receiving by human is related to medical radiation exposures, and also Computed Tomography (CT) is a special type of radiography that is one of the main method of radiation exposure today, and it's growing increasingly. Therefore, radio technologists working in CT scan imaging centers, are at risk of radiation. Due to the high am...

متن کامل

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Medical Association of Thailand = Chotmaihet thangphaet

دوره 92 6  شماره 

صفحات  -

تاریخ انتشار 2009