Measurement of gastric meal and secretion volumes using magnetic resonance imaging.
نویسندگان
چکیده
MRI can assess multiple gastric functions without ionizing radiation. However, time consuming image acquisition and analysis of gastric volume data, plus confounding of gastric emptying measurements by gastric secretions mixed with the test meal have limited its use to research centres. This study presents an MRI acquisition protocol and analysis algorithm suitable for the clinical measurement of gastric volume and secretion volume. Reproducibility of gastric volume measurements was assessed using data from 10 healthy volunteers following a liquid test meal with rapid MRI acquisition within one breath-hold and semi-automated analysis. Dilution of the ingested meal with gastric secretion was estimated using a respiratory-triggered T1 mapping protocol. Accuracy of the secretion volume measurements was assessed using data from 24 healthy volunteers following a mixed (liquid/solid) test meal with MRI meal volumes compared to data acquired using gamma scintigraphy (GS) on the same subjects studied on a separate study day. The mean ± SD coefficient of variance between 3 observers for both total gastric contents (including meal, secretions and air) and just the gastric contents (meal and secretion only) was 3 ± 2% at large gastric volumes (>200 ml). Mean ± SD secretion volumes post meal ingestion were 64 ± 51 ml and 110 ± 40 ml at 15 and 75 min, respectively. Comparison with GS meal volumes, showed that MRI meal only volume (after correction for secretion volume) were similar to GS, with a linear regression gradient ± std err of 1.06 ± 0.10 and intercept -11 ± 24 ml. In conclusion, (i) rapid volume acquisition and respiratory triggered T₁ mapping removed the requirement to image during prolonged breath-holds (ii) semi-automatic analysis greatly reduced the time required to derive measurements and (iii) correction for secretion volumes provided accurate assessment of gastric meal volumes and emptying. Together these features provide the scientific basis of a protocol which would be suitable in clinical practice.
منابع مشابه
Measuring the interaction of meal and gastric secretion: a combined quantitative magnetic resonance imaging and pharmacokinetic modeling approach.
BACKGROUND The stimulation and intragastric accumulation of gastric secretion has been recognized as an important factor in gastroesophageal reflux disease. However, the interaction of gastric secretion and meal emptying has not been fully understood. Current methods to assess gastric secretion are either invasive or unable to provide information on its volume, distribution and dynamics. The ai...
متن کاملThe effect of macronutrients on gastric volume responses and gastric emptying in humans: A magnetic resonance imaging study.
The effects of macronutrients on gastric volume changes, emptying, and gastrointestinal symptoms are incompletely understood. Three liquid meals of 500 ml (fat emulsion, 375 kcal; protein solution, 375 kcal; glucose solution, 400 kcal) were infused into the stomach of 12 healthy volunteers on three occasions. Studies were performed in seated body position using an open-configuration magnetic re...
متن کاملSexual Dimorphism in Volume of the Cerebral Hemispheres and Lateral Ventricles in Schizophrenia Using Magnetic Resonance Imaging
Purpose: This study is designed to determine the sexual dimorphism pattern in volume of the cerebral hemispheres and lateral ventricles in schizophrenia using magnetic resonance imaging (MRI) and to compare it with normal sexual dimorphism pattern in healthy brains. Materials and Methods: This study is performed on 29 healthy volunteers (21 males, 8 females) and 29 patients suffered from schiz...
متن کاملStatic Coil Design Considerations for the Magnetic Resonance Imaging
One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...
متن کاملGastric secretion does not affect the reliability of the 13C-acetate breath test: A validation of the 13C-acetate breath test by magnetic resonance imaging.
BACKGROUND (13)C-Acetate labeled meals are widely used to determine meal emptying by means of analyzing resulting (13)CO(2) exhalation dynamics. In contrast to the underlying metabolic processes, only few (13)C breath test meal emptying studies have focused on intragastric processes that may alter (13)CO(2) exhalation. This work assessed the effect of enhanced gastric secretion on the reliabili...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 60 3 شماره
صفحات -
تاریخ انتشار 2015