Drug-Eluting Stent: A Review and Update
نویسندگان
چکیده
The development of stent has been a major advance in the treatment of obstructive coronary artery disease since the introduction of balloon angioplasty. However, neointimal hyperplasia occurring within the stent leading to in-stent restenosis is a main obstacle in the long-term success of percutaneous coronary intervention (PCI). The recent introduction of drug-eluting stents (DES) contributes a major breakthrough to interventional cardiology. Many large randomized clinical trials using DES have shown a remarkable reduction in angiographic restenosis and target vessel revascularization when compared with bare metal stents. The results of these trials also appear to be supported by evidence from everyday practice and non-controlled clinical trials. However, the expanded applications of DES, especially in treating complex lesions such as left main trunk, bifurcation, saphenous vein graft lesions, or in-stent restenosis, are still under evaluation with ongoing studies. With the availability of different types of DES in the market, the issue of cost should not be a deterrent and DES will eventually be an economically viable option for all patients. The adoption of DES in all percutaneous coronary intervention may become a reality in the near future. In this review article, we summarize the recent development and progress of DES as well as compare and update the results of clinical trials.
منابع مشابه
Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent
Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...
متن کاملAssociation of G22A variant of Adenosine Deaminase gene with coronary in-stent restenosis in coronary artery patients receiving drug-eluting stent
In-stent restenosis (ISR) is regarded as the main problem in the utilization of stents in the treatment of coronary artery atherosclerotic stenosis in percutaneous coronary intervention (PCI). This study investigated the possible role of the G22A variant of the Adenosine Deaminase gene (ADA) in the development of ISR. In this study, 91 patients who underwent PCI were divided into two groups of ...
متن کاملUpdate on the everolimus-eluting coronary stent system: results and implications from the SPIRIT clinical trial program
Drug-eluting stents (DES) have had a major impact in interventional cardiology. Compared to bare metal stents, they significantly reduce restenosis and the need for target vessel revascularization. Four DES are available in the US, the first-generation sirolimus-eluting (Cypher((R))) and paclitaxel-eluting (Taxus((R))) stents and later approved second-generation everolimus-eluting (Xience V((R)...
متن کاملنتایج بالینی پس از آنژیوپلاستی عروق کرونر، بروز حوادث بزرگ قلبی-عروقی و عوارض انواع استنت
Background: Cardiovascular diseases alone have become the leading cause of death worldwide. One of the treatment methods cardiovascular disease is angioplasty. This study aimed to investigate the clinical results after coronary artery angioplasty, based on the incidence of major cardiovascular events with emphasis on stent types. Methods: In this retrospective cross-sectional study, the preval...
متن کاملA three-dimensional mathematical model for drug delivery from drug-eluting stents
Current drug-eluting stent (DES) technology is not optimized with regard to the pharmacokinetics of drug release, more research on the <span style="font-size: 12pt; color: #000000; font-style: normal; ...
متن کاملThe Ultimaster Biodegradable-Polymer Sirolimus-Eluting Stent: An Updated Review of Clinical Evidence
The Ultimaster coronary stent system (Terumo Corporation, Tokyo, Japan) represents a new iteration in drug-eluting stent (DES) technology that has recently received the Conformité Européenne (CE) mark approval for clinical use. The Ultimaster is a thin-strut, cobalt chromium, biodegradable-polymer, sirolimus-eluting coronary stent. The high elasticity of the biodegradable-polymer (PDLLA-PCL) an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vascular Health and Risk Management
دوره 1 شماره
صفحات -
تاریخ انتشار 2005