A Highly Simplified Thermionic Control of Temperature.
نویسندگان
چکیده
Three recent articles (1, 2, 3) describe methods of heat control which seem unnecessarily complicated in view of the present technical development of control tubes in the radio industry. Those methods, just mentioned, use mechanical relays and have wiring schemes which, although not complicated to those acquainted with radio, are nevertheless too difficult for many people to construct. One of the simplest and most effective schemes involving the use of thyratron tubes and no mechanical relays was described by SCHWENK and NOBLE (4) in 1937. The scheme here described is a further simplification and adaptation of thyratron methods. Recently two well-controlled incubators were needed and were obtained by converting two old ovens that had long been around the laboratory unused. These ovens had been controlled by the usual mechanical thermostat and allowed a temperature variation of + 20 C. The conversion of the ovens to valuable incubators was done as follows:' A five-volt transformer was mounted on top of the oven with the primary connected to the 110-volt line and the secondary connected to the two large prongs of a four-prong socket as filament supply for the control tube. Then the two heavy wires (the 110-volt line for the heater) that had led to the mechanical thermostat were disconnected and one of them soldered to the two small prongs (cathode and shield grid) of the four-prong socket. The other wire was soldered to a clip to attach to the tip (anode) of the control ttbe. The tube is now wired with plate and filament voltage and all that remains is to connect to the new thermostat. Any type of thermostat can be used. For the ovens just mentioned, coiled bimetallic thermostats were taken out of ten-cent store thermonmeters. The thermostat was left mounted on the metallic dial of the thermometer, but the hand was broken off and a short shaft soldered in its plaee. An insulated contact was mounted so the free end of the thermostat could touch it. The thermostat was then mounted inside the oven with the shaft sticking through the top of the oven. An ordinary dial was attached to the shaft. Adjustment for any range is obtained by turning this dial which winds up or unwinds the bimetallic thermostat. The wiring is completed by attaching one contact of the thermostat directly to the control grid, while the other one is connected to the anode through a 10-megohm resistance.
منابع مشابه
Advances in Thermionic Energy Conversion through Single-Crystal n-Type Diamond
Thermionic energy conversion, a process that allows direct transformation of thermal to electrical energy, presents a means of efficient electrical power generation as the hot and cold side of the corresponding heat engine are separated by a vacuum gap. Conversion efficiencies approaching those of the Carnot cycle are possible if material parameters of the active elements at the converter, i.e....
متن کاملBeta Radiation Enhanced Thermionic Emission from Diamond Thin Films
Diamond-based thermionic emission devices could provide a means to produce clean and renewable energy through direct heat-to-electrical energy conversion. Hindering progress of the technology are the thermionic output current and threshold temperature of the emitter cathode. In this report, we study the effects on thermionic emission caused by in situ exposure of the diamond cathode to beta rad...
متن کاملNumerical Modeling of Abrupt Heterojunctions Using a Thermionic-field Emission Boundary Condition
We present a numerical model in which the thermionic and tunneling mechanisms across an abrupt heterojunction interface are taken into account on the basis of the one dimensional drift-diffusion formulation. We use an expression of thermionic-field emission current formulated based on the WKB approximation as a boundary condition at the abrupt heterointerface which eventually limits the current...
متن کاملSolid-State and Vacuum Thermionic Energy Conversion
A brief overview of the research activities at the Thermionic Energy Conversion (TEC) Center is given. The goal is to achieve direct thermal to electric energy conversion with >20% efficiency and >1W/cm power density at a hot side temperature of 300-650C. Thermionic emission in both vacuum and solid-state devices is investigated. In the case of solid-state devices, hot electron filtering using ...
متن کاملCadmium Oxide Thin Films Deposited by a Simplified Spray Pyrolysis Technique for Optoelectronic Applications
Cadmium oxide thin films were fabricated on glass substrates by a simplified and low cost spray pyrolysis technique at different substrate temperatures. The X-ray diffraction study showed that irrespective of substrate temperature all the films exhibits a preferential orientation along the (1 1 1) plane. The values of crystallite size were found to be in the range 20.72 – 29.6 nm. The perce...
متن کاملOn the accuracy of thermionic electron emission models. I. Electron detachment from SF6(-).
Detailed statistical rate calculations combined with electron capture theory and kinetic modeling for the electron attachment to SF(6) and detachment from SF(6)(-) [Troe et al., J. Chem. Phys. 127, 244303 (2007)] are used to test thermionic electron emission models. A new method to calculate the specific detachment rate constants k(det)(E) and the electron energy distributions f(E,epsilon) as f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Plant physiology
دوره 16 3 شماره
صفحات -
تاریخ انتشار 1941