Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry.
نویسندگان
چکیده
Multi-wavelength photometers, blood gas analysers and pulse oximeters are widely used to measure various oxygen-related quantities. The definitions of these quantities are not always correct. This paper gives insight in the various definitions for oxygen quantities. Furthermore, the possible influences of dyshaemoglobins and fetal haemoglobin on the accuracy of pulse oximetry are discussed. As pulse oximeters are constructed for the determination of arterial oxygen saturation, they should be validated with sample oxygen saturation values and not with the oxyhaemoglobin fraction. The influence of carboxyhaemoglobin is insubstantial over an oxygen saturation range of 0% to 100%. Through the presence of methaemoglobin, pulse oximetry will give an underestimation above 70% and an overestimation below 70% oxygen saturation. The influence of fetal haemoglobin is insignificant in the neonatal use of pulse oximetry, in the range of 75% to 100% arterial oxygen saturation. However, a pulse oximeter underestimates the arterial oxygen saturation at the 25% level with 5%, if the pulse oximeter has been calibrated in human adults. Such a low level of arterial oxygen saturation can be present in the fetus during labor.
منابع مشابه
A Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination
Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...
متن کاملA New Method for Fingerprint Antispoofing using Pulse Oximetry
The deployment of fingerprint sensors is increasingly becoming common and has now gained high user acceptance. However, fingerprint sensors are susceptible to spoofing using artificial materials or in worst case to the dismembered fingers. Fake/gummy fingerprints have shown to fool most commercial fingerprint systems. This paper proposes a new method of anti-spoofing using reliable liveness det...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملEvaluation and Improvement of Knowledge of Medical staff on Pulse Oximetry in Educational Hospitals
Background: Pulse Oximeter monitoring has become so common over previous decades that in some health care units, blood oxygen level is now considered as the fifth vital sign. However, it seems there is still some lack of knowledge and/or experience among medical staff operating pulse oximeter and interpreting its results. The aim of this study was to investigate and compare the knowledge on Pul...
متن کاملAccuracy of noninvasive haemoglobin measurement by pulse oximetry depends on the type of infusion fluid: Retraction.
CONTEXT Measurement of blood haemoglobin concentration by pulse oximetry could be of value in determining when erythrocytes should be transfused during surgery, but the effect of infusion fluids on the results is unclear. OBJECTIVE To study the effect of crystalloid and colloid fluid on the accuracy (bias) and precision of pulse oximetry haemoglobin estimation to indicate the venous haemoglob...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta anaesthesiologica Scandinavica. Supplementum
دوره 107 شماره
صفحات -
تاریخ انتشار 1995