The Vertical Structure of Low-Frequency Motions in the Nearshore. Part II: Theory

نویسندگان

  • THOMAS C. LIPPMANN
  • ANTHONY J. BOWEN
چکیده

Field observations from a vertical stack of two-component current meters obtained from the 1994 Duck94 nearshore field experiment (presented in a companion paper by Lippmann, et al.) show significant vertical structure in energy, phase, and rotation of motions at low frequencies around 0.005Hz. Low-frequency motions are typically modeled in the surfzone with the shallow-water (depth averaged) momentum equations that do not allow for any vertical structure. Following work from the shelf tidal community (Prandle), this study shows that the observations are consistent with the depth-varying momentum equations including shear stresses induced by a bottom boundary layer described by a constant eddy viscosity nt and bottom friction given by a constant drag coefficient and depth-averaged velocity cdjWj. The bidirectional flow field is solved over arbitrary depth profiles varying only in the cross-shore direction h(x) in the presence of a vertically uniform mean alongshore current with cross-shore shear structure V(x). Analytic solutions are found to depend on nt, cd, h, ›V/›x, and the parameter p5 [i(kV2s1 ›V/›x)/nt] 1/2 5 il, where s and k are the radian frequency and alongshore wavenumber of the oscillating motion. Model behavior is explored by plotting solutions for a given parameter space as functions of the nondimensional depth H 5 lh and dimensionless friction parameter J5 ntl/cdjWj that combines the effects of bottom drag and vertical mixing. The behavioral changes in amplitude, phase shift, and rotational structure over the water column are qualitatively similar to those observed in the field.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vertical response of short and long span suspension bridges due to near and far fault earthquakeshttps://jeg.khu.ac.ir/files/site1/yekta_program/bb/tmpl_yekta/bb_end.gif

Many researches have been currently conducted on the effects of fault distance on structures revealing that their seismic response can differ according to their distance from the fault. Suspension bridges due to their long period and high flexibility can be more sensitive to this phenomenon, especially in vertical vibration. Since the engineers tend to use longer spans, the length factor should...

متن کامل

Beyond first order logic: From number of structures to structure of numbers: Part II

We study the history and recent developments in nonelementarymodel theory focusing on the framework of abstractelementary classes. We discuss the role of syntax and semanticsand the motivation to generalize first order model theory to nonelementaryframeworks and illuminate the study with concrete examplesof classes of models. This second part continues to study the question of catecoricitytrans...

متن کامل

Simplified Seismic Dynamic Analysis of Sloshing Phenomenon in Rectangular Tanks with Multiple Vertical Baffles

Sloshing is a well-known phenomenon in liquid storage tanks subjected to base or body motions. In recent years the use of multiple vertical baffles for reducing the sloshing effects in tanks subjected to earthquake has not been taken into consideration so much. On the other hand, although some of the existing computer programs are capable to model sloshing phenomenon with acceptable accuracy, t...

متن کامل

Dynamic Response of Submerged Vertical Cylinder with Lumped Mass under Seismic Excitation

An analytical approach is presented to assess the response of offshore structures under seismic excitation. This paper evaluates the impacts of different fluid field models and the mass of equipment at the top of offshore structure which is simulated as lumped mass on the responses of offshore structures. To do this, two and three dimensional fluid field models are developed. In three dimension...

متن کامل

Characteristics of Horizontal and Vertical Near-Field Ground Motions and Investigation of Their Effects on the Dynamic Response of Bridges

Recently, concerning failure of structures due to earthquakes, special investigations of near fault ground motions have been noticed. Hence, in this paper, characteristics of near field ground motions have been considered in horizontal and vertical directions. In this consideration, the record averages have been compared with Uniform Building Code and Eurocode8 spectra in two levels. In additio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016