Comparison of chemically and pharmaceutically modified titanium and zirconia implant surfaces in dentistry: a study in sheep.
نویسندگان
چکیده
Advanced surface modifications and materials were tested on the same implant geometry. Six types of dental implants were tested for osseointegration after 2, 4 and 8 weeks in a sheep pelvis model. Four titanium implant types were treated with newly developed surface modifications, of which two were chemically and two were pharmacologically modified. One implant was made of zirconia. A sandblasted and acid-etched titanium surface was used as reference. The chemically modified implants were plasma-anodized or coated with calcium phosphate. The pharmacological coatings contained either bisphosphonate or collagen type I with chondroitin sulphate. The implants were evaluated using macroscopic, radiographic and histomorphometric methods. All implants were well osseointegrated at the time of death. All titanium implants had similar bone implant contact (BIC) at 2 weeks (57-61%); only zirconia was better (77%). The main BIC increase was between 2 and 4 weeks. The pharmacologically coated implants (78-79%) and the calcium phosphate coating (83%) showed similar results compared with the reference implant (80%) at 8 weeks. There were no significant differences in BIC. Compared with previous studies the results of all implants were comparatively good.
منابع مشابه
Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...
متن کاملComparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملOsseointegration of zirconia implants with different surface characteristics: an evaluation in rabbits.
PURPOSE Zirconia ceramics are a viable alternative to titanium for use as dental implants. However, the smooth surface of zirconia means that longer healing periods are needed to accomplish osseointegration compared to roughened titanium surfaces. Surface modifications can be used to increase the roughness of zirconia. The aim of this study was to assess histologically and compare the degree of...
متن کاملOsseointegration of zirconia implants: an SEM observation of the bone-implant interface
BACKGROUND The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of oral and maxillofacial surgery