چکیده

OBJECTIVE To investigate whether miscarried embryo/fetal crown rump length (CRL) measurement may yield a practical application for predicting a conclusive result at the cytogenetic analysis of miscarriage tissue. Our study might help in improving the cytogenetic method, the results of which may be affected by maternal cell contamination (MCC). In particular, we aimed at establishing whether the miscarried embryo/fetal CRL measurement shows accuracy in predicting the possibility of MCC and the scan cut-off value useful to this purpose and, as a result, suggest a multi-step procedure for the genetic ascertainment. METHODS Women experiencing at least two miscarriages of less than 20 weeks size at the Pregnancy Loss Unit at Fondazione Policlinico A. Gemelli underwent a scan before surgery. The CRL value was recorded. After the dilatation and courettage (D&C) procedure, miscarriage tissue was processed through the proposed multi-step procedure before performing oligo-nucleotide-based and SNP (single nucleotide polymorphisms)-based comparative genomic hybridization (CGH+SNP) microarray analysis. RESULTS 63 women and 63 miscarriages met the criteria. By using the Receiving Operator Characteristic (ROC) curves, CRL showed an AUC of 0.816 (95%CI:0.703-0.928,p<0.001). A CRL≥24.5 mm cut-off value showed a higher positive likelihood ratio (5.27) but, conversely, a higher negative likelihood ratio (0.64) in predicting the possibility of MCC. Microarray analysis was successful in the totality of cases in which the embryo/fetal origin of miscarriage tissues was proven. CONCLUSIONS The 24.5 mm CRL value emerges as the most suitable cut-off enabling the identification of cases in which the embryo-fetal component can be isolated in the absence of MCC and the chromosomal array provide informative results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A logistic model to predict early pregnancy loss following in vitro fertilization based on 2601 infertility patients

BACKGROUND According to previous studies, even after embryonic cardiac activity is detected, the pregnancy loss rate remains 3-4 %. The objectives of this study were to investigate the differences in ultrasound parameters between a miscarriage group and an ongoing pregnancy group during the 1(st) trimester and to build a logistic model to predict early pregnancy loss (EPL) after the appearance ...

متن کامل

Correlation of Serum CA-125 and Progesterone Levels with Ultrasound Markers in The Prediction of Pregnancy Outcome in Threatened Miscarriage

Background The aim of this study was to evaluate the relationship between ultrasonographic findings and serum progesterone and cancer antigen-125 (CA-125) levels in threatened miscarriage and to predict pregnancy outcome. MaterialsAndMethods In a prospective comparative case-control study, serum CA-125 and progesterone levels were measured for 100 pregnant women with threatened miscarriage who ...

متن کامل

First-trimester fetal growth restriction and the occurrence of miscarriage in rural Bangladesh: A prospective cohort study

Fetal growth restriction in early pregnancy increases the risk of adverse pregnancy outcome, which has a significant social and psychological impact on women. There is limited information related to community-based study to evaluate early indicators related to miscarriage. The aim of this study is to examine the relationship between fetal growth restriction, measured by ultrasound crown-rump le...

متن کامل

Re: limitations of current definitions of miscarriage using mean gestational sac diameter and crown-rump length measurements: a multicenter observational study.

OBJECTIVES There is significant variation in cut-off values for mean gestational sac diameter (MSD) and embryo crown-rump length (CRL) used to define miscarriage, values suggested in the literature ranging from 13 to 25 mm for MSD and from 3 to 8 mm for CRL. We aimed to define the false-positive rate (FPR) for the diagnosis of miscarriage associated with different CRL and MSD measurements with ...

متن کامل

Nuchal translucency in normal fetus and its variation with increasing crown rump length (CRL) and gestational age.

BACKGROUND Nuchal translucency (NT) is the fluid collection behind the fetal neck which can be measured by ultrasound at 11-14 weeks of gestation. Increase in the nuchal translucency thickness is associated with various congenital anomalies. OBJECTIVE To study the relationship between nuchal translucency thickness, crown rump length and gestational age in normal fetus. METHODS Prospective a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017