The Effect of Diluted Penetration Enhancer in Nebulized Mist versus Liquid Drop Preparation Forms on Retrobulbar Blood Flow in Healthy Human Subjects

نویسندگان

  • Sally Primus
  • Ingrida Januleviciene
  • Brent Siesky
  • Austin Gerber
  • Patrick Egan
  • Annahita Amireskandari
  • Lina Siaudvytyte
  • Ruta Barsauskaite
  • Alon Harris
چکیده

The aim of this study was to compare the effects of nebulized mist and liquid drop applications on retrobulbar blood flow. A prospective, non-randomized clinical trial was used to collect data from 40 healthy human eyes. Color Doppler Imaging determined peak systolic (PSV) and end diastolic (EDV) blood flow velocities and resistance index (RI) in the ophthalmic artery after both applications. Measurements were taken at baseline and at 1 min post-treatment in both eyes with 5 min measurements in the treatment eye only. p values ≤ 0.05 were considered statistically significant. Mist application to treatment eye produced an increase in 1 min and 5 min PSV and EDV (0.001 < p < 0.03) and a decrease in 5 min RI (p = 0.01), with no significant changes in PSV, EDV or RI of control eye or in treatment eye 1 min RI (p > 0.05). Drop application to treatment eye produced an increase in PSV (p < 0.001) and EDV (p = 0.01) at 1 min, with an increase in control eye 1 min PSV and EDV (p = 0.03). There were no statistically significant changes in treatment eye PSV, EDV and RI after 5 min (p > 0.05). The use of nebulized mist may provide an effective alternative to liquid drop medication application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Dimethyl Sulfoxide as a Penetration Enhancer of Piroxicam Gel Through Biological Skin

      Piroxicam is a non-steroidal anti-inflammatory agent which has an extensive use in rheumatic disorders. Since its skin penetration is still a subject for research, the aim of this study was to evaluate the effect of dimethyl sulfoxide on percutaneous penetration of piroxicam gel formulation through skin. In this study, as a model, two types of 0.5% piroxicam new gels, so called red and gr...

متن کامل

Effect of Nondimensional Parameters On the Internal Circulation of a Liquid Drop Moving with the Surrounding Gas

The internal flow circulation dynamics of a liquid drop moving in a co- or counter-flowing gas stream has been numerically studied. The present work is concerned with the time accurate numerical solution of the two phase flow field at the low Mach number limit with an appropriate volume tracking method to capture motion and deformation of a liquid drop. It is shown that relative velocity betwee...

متن کامل

High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies

A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...

متن کامل

High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies

A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...

متن کامل

Effect of Nondimensional Parameters On the Internal Circulation of a Liquid Drop Moving with the Surrounding Gas

The internal flow circulation dynamics of a liquid drop moving in a co- or counter-flowing gas stream has been numerically studied. The present work is concerned with the time accurate numerical solution of the two phase flow field at the low Mach number limit with an appropriate volume tracking method to capture motion and deformation of a liquid drop. It is shown that relative velocity betwee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012