Relationship between tissue characterization with 40 MHz intravascular ultrasound imaging and 64-slice computed tomography.
نویسندگان
چکیده
BACKGROUND Identification of coronary plaque composition is important for selecting the treatment strategy, and 64-slice computed tomography (CT) is a noninvasive method of characterizing atherosclerotic plaques. However, the correlation between plaque characteristics detected by CT and intravascular ultrasound (IVUS) is not clear. A 40 MHz IVUS imaging system (iMap-IVUS) has recently been developed to evaluate plaque composition. The aim of this study was to compare iMap-IVUS with 64-slice CT angiography for the characterization of non-calcified coronary plaques. METHODS AND RESULTS Both 64-slice CT angiography and iMap-IVUS were performed in 19 patients (38 plaques). CT values were measured as Hounsfield units (HU) in circular regions of interest (ROI) drawn on the plaques. The iMap-IVUS system analyzed coronary plaques as fibrotic, lipidic, necrotic, or calcified tissue based on the radiofrequency spectrum. A positive correlation was found between CT values and the percentage of fibrotic plaque (r=0.34, p=0.036) or calcified plaque (r=0.40, p=0.011). Conversely, a negative correlation was found between CT values and the percentage of lipidic plaque (r=-0.41, p=0.01), or necrotic plaque (r=-0.41, p=0.01). CONCLUSIONS Good correlations were observed between the characteristics of non-calcified plaque determined by iMap-IVUS and the CT values of plaque detected by 64-slice CT scanning.
منابع مشابه
Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of Coronary Lumen in Segments with or without Atherosclerotic Plaques
BACKGROUND The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. OBJECTIVES We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehe...
متن کاملApplication of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کاملNew imaging techniques for diagnosing coronary artery disease.
New tomographic cardiovascular imaging tests, such as intravascular ultrasonography (IVUS), coronary computed tomography (CT) angiography and magnetic resonance imaging (MRI), can be used to assess atherosclerotic plaques for the characterization and early staging of coronary artery disease (CAD). Although IVUS images have very high resolution capable of revealing very early preclinical CAD, it...
متن کاملAccuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound.
OBJECTIVES We evaluated the accuracy of a new 64-slice computed tomography (CT) scanner, compared with intravascular ultrasound, to visualize atherosclerosis in the proximal coronary system. BACKGROUND Noninvasive determination of plaque composition and plaque burden may be important to improve risk stratification. METHODS In 20 patients, a 64-slice CT scan (Sensation 64, Siemens Medical So...
متن کاملAtherosclerotic plaque characterization by 0.5-mm-slice multislice computed tomographic imaging.
BACKGROUND It has been proposed that 0.5-mm-slice multislice computed tomography (MSCT) is a noninvasive tool for the detection of atherosclerotic plaque, but the validity of such an assessment has not been demonstrated by an invasive investigation. The present study was performed to compare the 0.5-mm-slice MSCT density of plaques with intravascular ultrasound (IVUS) findings. METHODS AND RE...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiology
دوره 57 3 شماره
صفحات -
تاریخ انتشار 2011