Partial bowls using the Haemonetics Cell Saver 5: does it produce a quality product?
نویسندگان
چکیده
Controversy still exists on the validity of processing a partial bowl during the collection of shed blood lost through surgery during cell salvaging. The purpose of this study was to assess the quality of red blood cells produced from a partial bowl of autologous suctioned blood using the Haemonetics Cell Saver 5. Suctioned blood was collected from 17 patients undergoing cardiac surgery. A partially filled cell saver bowl was washed with 1500 mL of NaCl. Reservoir and processed blood samples were examined for potassium, leukocytes, hematocrit, platelets, and plasma-free hemoglobin and then compared with 22 previously studied full bowls. Results are summarized in the table below: In conclusion, the Haemonetics Cell Saver 5 can produce a quality product from washing a partial bowl with a better washout of white blood cells compared with a full bowl. However, there is a reduction in red blood cell recovery.
منابع مشابه
Quality of red blood cells using autotransfusion devices: a comparative analysis.
Cell salvage devices are routinely used to process and wash red blood cells (RBCs) shed during surgical interventions. Although the principle theory of cell saving is the same, the actual process to achieve this is very different from one device to another. The purpose of this study was to compare the quality of washed, concentrated RBC produced by five very different cell-saving devices, speci...
متن کاملEffect of partial-filling autotransfusion bowls on the quality of reinfused product.
Intraoperative autotransfusion is used in a variety of surgical procedures with the quantity of blood loss dependent upon numerous factors. These procedures may or may not produce a full autotransfusion bowl. The inadequate removal of contaminants has been correlated to the incomplete filling of bowls, resulting in a condition called "Salvaged Blood Syndrome." The purpose of this study was to a...
متن کاملImpact of blood salvage during liver transplantation on reduction in transfusion requirements.
PURPOSE The aim of this study was to analyse the changes in transfusion requirements, in patients submitted to orthotopic liver transplantation from cadaveric donors, with the use of intraoperative red blood cell salvage (Cell Saver). METHODS Data from 41 transplants were analysed. Intraoperative blood loss was calculated from the cell salvage, suction and the swabs. The autologous and hetero...
متن کاملQuantitative and qualitative analysis of platelet-rich plasma collection using the Haemonetics Cell Saver 5 in open heart surgery.
Many traditional autologous blood recovery systems (ABRSs) have undergone modifications to enable them to collect platelet-rich plasma (PRP). Because of the growing demand for autologous platelet gel (APG) in cardiac surgery, many open heart teams are faced with the choice of using their existing ABRS or purchasing a dedicated PRP device. This study was conducted to address the issues we had ab...
متن کاملDebris elimination from partially-filled cell salvage bowls.
Centrifuge-based cell salvage and washing systems, available since the 1970s, have decreased the use of allogeneic blood transfusions (1). Although intraoperative salvage and autotransfusion avoids the risks of allogeneic transfusion, case reports document adverse reactions to this blood, potentially related to inadequate washing (2). The cleanliness of partially filled cell salvage bowls has b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 37 2 شماره
صفحات -
تاریخ انتشار 2005