Fundamental sensitivity limit imposed by dark 1/f noise in the low optical signal detection regime.
نویسندگان
چکیده
The impact of dark 1/f noise on fundamental signal sensitivity in direct low optical signal detection is an understudied issue. In this theoretical manuscript, we study the limitations of an idealized detector with a combination of white noise and 1/f noise, operating in detector dark noise limited mode. In contrast to white noise limited detection schemes, for which there is no fundamental minimum signal sensitivity limit, we find that the 1/f noise characteristics, including the noise exponent factor and the relative amplitudes of white and 1/f noise, set a fundamental limit on the minimum signal that such a detector can detect.
منابع مشابه
Weak Force Measurement in Bistable Optomechanical System
One of the main milestones in the study of opto-mechanical system is to increase the sensitivity of weak forces measurement up to the standard quantum limit. We have studied the detection of weak force under a bistable condition in red detuned regime. In this case, dynamics of the system behaves asymptotically similar to stationary state and applying external force affects phase and fluctuation...
متن کاملA Decision between Bayesian and Frequentist Upper Limit in Analyzing Continuous Gravitational Waves
Given the sensitivity of current ground-based Gravitational Wave (GW) detectors, any continuous-wave signal we can realistically expect will be at a level or below the background noise. Hence, any data analysis of detector data will need to rely on statistical techniques to separate the signal from the noise. While with the current sensitivity of our detectors we do not expect to detect any tru...
متن کاملThe advantage of using a diode laser instead of a Q-switched laser in photoacoustic imaging of tissues
Photoacoustic (PA) imaging of biological tissues using laser diodes instead of conventional Q switched pulsed systems provides an attractive alternative for biomedical applications. However, the relatively low energy of laser diodes operating in the pulsed regime, results in generation of very weak acoustic waves, and low signal-to-noise ratio (SNR) of the detected signals. This problem can be ...
متن کاملSqueezed Light for the Interferometric Detection of High Frequency Gravitational Waves
The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where i...
متن کاملRTS Noise and Dark Current White Defects Reduction Using Selective Averaging Based on a Multi-Aperture System
In extremely low-light conditions, random telegraph signal (RTS) noise and dark current white defects become visible. In this paper, a multi-aperture imaging system and selective averaging method which removes the RTS noise and the dark current white defects by minimizing the synthetic sensor noise at every pixel is proposed. In the multi-aperture imaging system, a very small synthetic F-number...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 16 10 شماره
صفحات -
تاریخ انتشار 2008