Three-dimensional photoacoustic tomography based on the focal-line concept.

نویسندگان

  • Jun Xia
  • Zijian Guo
  • Konstantin Maslov
  • Andres Aguirre
  • Quing Zhu
  • Christopher Percival
  • Lihong V Wang
چکیده

A full ring ultrasonic array-based photoacoustic tomography system was recently developed for small animal brain imaging. The 512-element array is cylindrically focused in the elevational direction, and can acquire a two-dimensional (2D) image in 1.6 s. In this letter, we demonstrate the three-dimensional (3D) imaging capability of this system. A novel 3D reconstruction algorithm was developed based on the focal-line concept. Compared to 3D images acquired simply by stacking a series of 2D images, the 3D focal-line reconstruction method renders images with much less artifacts, and improves the elevational resolution by 30% and the signal-to-noise ratio by two times. The effectiveness of the proposed algorithm was first validated by numerical simulations and then demonstrated with a hair phantom experiment and an ex vivo mouse embryo experiment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coherent-weighted three-dimensional image reconstruction in linear-array-based photoacoustic tomography

While the majority of photoacoustic imaging systems used custom-made transducer arrays, commercially-available linear transducer arrays hold the benefits of affordable price, handheld convenience and wide clinical recognition. They are not widely used in photoacoustic imaging primarily because of the poor elevation resolution. Here, without modifying the imaging geometry and system, we propose ...

متن کامل

Three-dimensional photoacoustic imaging using fiber-based line detectors.

For photoacoustic imaging, usually point-like detectors are used. As a special sensing technology for photoacoustic imaging, integrating detectors have been investigated that integrate the acoustic pressure over an area or line that is larger than the imaged object. Different kinds of optical fiber-based detectors are compared regarding their sensitivity and resolution in three-dimensional phot...

متن کامل

Experimental evaluation of reconstruction algorithms for limited view photoacoustic tomography with line detectors

A method for photoacoustic tomography is presented that uses line integrals over the acoustic wave field from a photoacoustic source for the reconstruction of a three-dimensional image. The line integrals are acquired with an optical line sensor based on a Mach–Zehnder interferometer. Image reconstruction is a two-step process. In the first step data from a scan of the line outside the object a...

متن کامل

Three-Dimensional Computed Tomography Diagnosis of Cranium Bifidum with Meningocele in a Lamb

Abstract   Case Description- A three-day-old male Kordi lamb had a soft painless fluctuating mass on the mid-parietal region, with no clinical signs except difficulty in standing; was referred to the clinic. Clinical Findings- Clinical examination revealed a normal body temperature, a heart rate, a respiratory rate, and inability to stand without any congenital defects Three-dimensional comp...

متن کامل

Award Number : W 81 XWH - 09 - 1 - 0299 TITLE : Photoacoustic Imaging of Epilepsy PRINCIPAL

A total-variation-minimization-based iterative algorithm is describ ed in this paper that enhances the quality of reconstructed images with time-domain data over that obtained previously with a regularized least-squares approach. ©2010 Optical Society of America OCIS codes: (110.6960) Tomography; (110.5120) Photoacoustic imaging

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 16 9  شماره 

صفحات  -

تاریخ انتشار 2011