An accelerator beam experiment was performed using a low-energy antiproton beam to measure the antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on geant/gheisha showed good agreement. With the detailed verification of the BESS simulation, results demonstrate that the relative systematic error of detection efficiency derived from the BESS simulation is within ± 5%, being previously estimated as ± 15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurements of Primary and Atmospheric Cosmic-Ray Spectra with the BESS-TeV Spectrometer

Primary and atmospheric cosmic-ray spectra were precisely measured with the BESS-TeV spectrometer. The spectrometer was upgraded from BESS-98 to achieve seven times higher resolution in momentum measurement. We report absolute fluxes of primary protons and helium nuclei in the energy ranges, 1–540 GeV and 1– 250 GeV/n, respectively, and absolute flux of atmospheric muons in the momentum range 0...

متن کامل

Measurement of the cosmic-ray low-energy antiproton spectrum with the first BESS-Polar Antarctic flight

The BESS-Polar spectrometer had its first successful balloon flight over Antarctica in December 2004. During the 8.5-day long-duration flight, almost 0.9 billion events were recorded and 1,520 antiprotons were detected in the energy range 0.1–4.2 GeV. In this paper, we report the antiproton spectrum obtained, discuss the origin of cosmic-ray antiprotons, and use antiproton data to probe the eff...

متن کامل

Measurement of cosmic-ray low-energy antiproton spectrum with the first BESS-Polar Antarctic flight

The BESS-Polar spectrometer had its first successful balloon flight over Antarctica in December 2004. During the 8.5-day long-duration flight, almost 0.9 billion events were recorded and 1,520 antiprotons were detected in the energy range 0.1– 4.2 GeV. In this paper, we report the antiproton spectrum obtained, discuss the origin of cosmic-ray antiprotons, and use antiprotons to probe the effect...

متن کامل

Precision measurement of cosmic-Ray antiproton spectrum

The energy spectrum of cosmic-ray antiprotons ( &pmacr;'s) has been measured in the range 0.18-3.56 GeV, based on 458 &pmacr;'s collected by BESS in a recent solar-minimum period. We have detected for the first time a characteristic peak at 2 GeV of &pmacr;'s originating from cosmic-ray interactions with the interstellar gas. The peak spectrum is reproduced by theoretical calculations, implying...

متن کامل

Efficiency determination for the ATRAP detector system

The ATRAP experiment at the CERN Antiproton decelerator (AD) aiming for a precise CPT test by studying the antihydrogen atom includes a detection system for the antiproton annihilation products. Antihydrogen production studies require the knowledge of the produced antihydrogen atoms as well as absolute antiproton losses during the development. In 2008 the ATRAP experiment has been modified by a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009