Accounting for filter bandwidth improves the quantitative accuracy of bioluminescence tomography.
نویسندگان
چکیده
Bioluminescence imaging is a noninvasive technique whereby surface weighted images of luminescent probes within animals are used to characterize cell count and function. Traditionally, data are collected over the entire emission spectrum of the source using no filters and are used to evaluate cell count/function over the entire spectrum. Alternatively, multispectral data over several wavelengths can be incorporated to perform tomographic reconstruction of source location and intensity. However, bandpass filters used for multispectral data acquisition have a specific bandwidth, which is ignored in the reconstruction. In this work, ignoring the bandwidth is shown to introduce a dependence of the recovered source intensity on the bandwidth of the filters. A method of accounting for the bandwidth of filters used during multispectral data acquisition is presented and its efficacy in increasing the quantitative accuracy of bioluminescence tomography is demonstrated through simulation and experiment. It is demonstrated that while using filters with a large bandwidth can dramatically decrease the data acquisition time, if not accounted for, errors of up to 200% in quantitative accuracy are introduced in two-dimensional planar imaging, even after normalization. For tomographic imaging, the use of this method to account for filter bandwidth dramatically improves the quantitative accuracy.
منابع مشابه
Incorporation of an ultrasound and model guided permissible region improves quantitative source recovery in bioluminescence tomography
Bioluminescence imaging has shown great potential for studying and monitoring disease progression in small animal pre-clinical imaging. However, absolute bioluminescence source recovery through tomographic multi-wavelength measurements is often hindered through the lack of quantitative accuracy and suffers from both poor localisation and quantitative recovery. In this work a method to incorpora...
متن کاملDetermination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging
Background: Butterworth, Gaussian, Hamming, Hanning, and Parzen are commonly used SPECT filters during filtered back-projection (FBP) reconstruction, which greatly affect the quality and size accuracy of image. Materials and Methods: This study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc conc...
متن کاملAn Adaptive Self-adjusting Bandwidth Bandpass Filter without IIR Bias
In this paper we introduce a simple, computationally inxepentsive, adaptive recursive structure for enhancing bandpass signals highly corrupted by broad-band noise. This adaptive algorithm, enhancing input signals, enables us to estimate the center frequency and the bandwidth of the input signal. In addition, an important feature of the proposed structure is that the conventional bias existing ...
متن کاملAn Adaptive Self-adjusting Bandwidth Bandpass Filter without IIR Bias
In this paper we introduce a simple, computationally inxepentsive, adaptive recursive structure for enhancing bandpass signals highly corrupted by broad-band noise. This adaptive algorithm, enhancing input signals, enables us to estimate the center frequency and the bandwidth of the input signal. In addition, an important feature of the proposed structure is that the conventional bias existing ...
متن کاملBioluminescence tomography with Gaussian prior
Parameterizing the bioluminescent source globally in Gaussians provides several advantages over voxel representation in bioluminescence tomography. It is mathematically unique to recover Gaussians [Med. Phys. 31(8), 2289 (2004)] and practically sufficient to approximate various shapes by Gaussians in diffusive medium. The computational burden is significantly reduced since much fewer unknowns a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomedical optics
دوره 20 9 شماره
صفحات -
تاریخ انتشار 2015