Salicylate determined with a microcentrifugal analyzer, and compared with Du Pont aca, trinder, and liquid-chromatographic methods.

نویسندگان

  • J H Eckfeldt
  • K M Nelson
چکیده

We describe a new automated method for measuring serum salicylate in the Multistat III microcentrifugal analyzer. Ferric nitrate reagent and serum blanking are used. We compare this new method, the automated Du Pont aca method, and the manual Trinder method with a "high-performance" liquid-chromatographic method. The unblanked Trinder method had the poorest correlation (r = 0.980, Sy X x = 19.1) with the chromatographic method. The serum-blanked aca and Multistat III methods showed better correlation (r = 0.995, Sy X x = 9.5 mg/L, and r = 0.991, Sy X x = 13.0 mg/L, respectively) with the chromatographic method. However, we conclude that all three colorimetric methods give clinically useful results and that the increased time, expense, and expertise required for chromatographic salicylate analysis are difficult to justify in a routine clinical laboratory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Negative interference with the Du Pont aca method for measuring digoxin.

In response to a recent Letter (1) concerning the digoxin method in the aca Discrete Clinical Analyzer, the Dii Pont Company would like to offer the following. As in any enzyme immunoassay, the possibility existsthattheenzyme could be either activated or inhibited by drugs and (or) nonspecific substances, resulting in reported values that do not reflect true concentrations of the drug. We have ...

متن کامل

Hemoglobin interference with Du Pont Automatic Clinical Analyzer procedure for calcium.

Hemoglobin in concentrations of approximately 2.5 g/liter or greater significantly increases values for apparent calcium in serum as determined with the Du Pont aca, an interference attributable to the 575-nm absorption band of oxyhemoglobin being uncompensated by the 577--600 nm differential absorption reading of the calcium o-cresolphthalein complexone complex.

متن کامل

Interlaboratory comparison of enzymatic methods for serum glucose determination.

This report describes an interlaboratory comparison of enzymatic serum glucose methods as currently applied in several instrumental adaptations. Four spectrophotometric, hexokinase-based methods used with the Du Pont "aca," the Abbott "Bichromatic Analyzer," the Aminco "Rotochem," and the Technicon "AutoAnalyzer ll" were compared with glucose oxidase-based methods as used with the Beckman "Gluc...

متن کامل

Source of error in cerebrospinal fluid protein determination with the Du Pont Automatic Clinical Analyzer.

To the Editor: The most widely used method for measurement of cerebrospinal fluid (CSF) total protein is turbidimetry. We use the Du Pont Automatic Clinical Analyzer (aca; Du Pont Instruments, Wilmington, Del. 19898) for this measurement. In this method, CSF proteins are precipitated by trichloroacetic acid and the resulting turbidity is measured spectrophotometrically (1). Values are falsely l...

متن کامل

An evaluation of the Du Pont aca IV: does it meet medical needs?

A new bench-top analyzer from Du Pont, the "aca IV," was evaluated. To do so, we performed 10 different tests during an eight-week test period. The instrument is very precise (CVs less than 2%), results agree well with those obtained with the older acas (II and III), linearity is good in the clinically important ranges, and there is very little drift or carryover. From a medical-needs viewpoint...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 1983