An In Vitro Comparison of Propex II Apex Locator to Standard Radiographic Method
نویسنده
چکیده
INTRODUCTION The aim of this in vitro study was to compare the accuracy of radiography in assessing working length to Propex II apex locator. MATERIALS AND METHODS Thirty single canal extracted human teeth with patent apical foramen were selected. Access cavities were prepared. Anatomic length (AL) was determined by inserting a K-file into the root canal until the file tip was just visible at the most coronal aspect of the apical foramen; subsequently 0.5 mm was deducted from this measured length. Working length by radiographic method (RL) was determined using Ingle's method. Propex II apex locator was used to determine the electronic working length (EL). From these calculated lengths, AL was deducted to obtain D-value. D-value in the range of +/-0.5 mm was considered to be acceptable. RESULTS The percentage accuracy of RL and Propex II apex locator was 76.6% and 86.6%, respectively. Paired t-test revealed significant difference between the RL and Propex II apex locator (P<0.05). CONCLUSION Under these in vitro conditions, Propex II apex locator has determined working length more accurately than radiographic method.
منابع مشابه
Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study
Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...
متن کاملPerformance in vitro of apex locators in determining root length in primary molars Desempenho in vitro de localizadores apicais na determinação de comprimento radicular em molares decíduos
Objective The aim of the study was to evaluate performance of digital radiographic and two electronic apex locators, Propex II and Root ZX in root canal length determination in primary molars. Methods 25 primary molars were divided into two groups, G1 without root resorption and G2 with root resorption. The exams were performed using all methods by two experienced examiners, with 1-week interva...
متن کاملEvaluation of the Use of Sixth Generation Apex Locators as a Diagnostic Tool to Detect Root Perforations
Aim: The sixth generation apex locators served as an efficient diagnostic tool for detecting root perforations as these are based on the principle of impedance rather than the conventional gradient method. However, their diagnostic accuracy not evaluated well. In the existing study, we assessed and compared the efficacy of two apex locators for diagnostic perspective. Materials and Methods: A t...
متن کاملA comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study
BACKGROUND Accurate working length determination is a pre-requisite for a successful endodontic treatment. Even with improved systems of working length measurement, different readings may be recorded in different electrolytes present in the canal. The purpose of this in vivo/ex vivo comparative study was to determine the accuracy in measuring the working length of root canal using Direct Digita...
متن کاملIn vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen
OBJECTIVES The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). MATERIALS AND METHODS Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal...
متن کامل