Self-Consistent Effective Equations Modeling Blood Flow in Medium-to-Large Compliant Arteries

نویسندگان

  • Suncica Canic
  • Daniele Lamponi
  • Andro Mikelic
  • Josip Tambaca
چکیده

We study the flow of an incompressible viscous fluid through a long tube with compliant walls. The flow is governed by a given time dependent pressure head difference. The Navier-Stokes equations for an incompressible viscous fluid are used to model the flow, and the Navier equations for a curved, linearly elastic membrane to model the wall. Employing the asymptotic techniques typically used in thin domains, we derive a set of effective equations that hold in medium-to-large compliant vessels for laminar flow regimes. The main novelty is the derivation of the effective equations that do not assume any ad hoc closure, typically assumed in the derivation of one-dimensional models. Using ideas from homogenization theory for porous media flows, we obtain a closed system of effective equations that are of Biot type with memory. Memory accounts for the wave-like phenomena in the problem. Although the equations are two-dimensional, their simple structure enables a design of a numerical algorithm that has complexity of a one-dimensional solver. Our numerical simulations show that our model captures two-dimensional effects that cannot be captured using standard one-dimensional methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Mathematical modeling of blood flow in a stenosed artery under MHD effect through porous medium

In this investigation, a mathematical model for studying oscillatory flow of blood in a stenosed artery under the influence of transverse magnetic field through porous medium has been developed. The equations of motion of blood flow are solved analytically. The analytical expressions for axial velocity, volumetric flow rate, pressure gradient, resistance to blood flow and shear stress have been...

متن کامل

برآورد سرعت موج پالس با استفاده از پارامترهای شریانی استخراج شده از تصاویر فراصوتی کاروتید

  Background & Objective : Several indices have been introduced to estimate arterial stiffness that based on changes in brachial blood pressure. But because of the error resulted by the substitution of brachial blood pressure instead of the other central arteries, such as carotid, it will be very important to present elastic parameter based on the mechanical models without any emphasis on brach...

متن کامل

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Multiscale Modeling & Simulation

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2005