Anatomical evaluation of CT-MRI combined femoral model

نویسندگان

  • Yeon S Lee
  • Jong K Seon
  • Vladimir I Shin
  • Gyu-Ha Kim
  • Moongu Jeon
چکیده

BACKGROUND Both CT and MRI are complementary to each other in that CT can produce a distinct contour of bones, and MRI can show the shape of both ligaments and bones. It will be ideal to build a CT-MRI combined model to take advantage of complementary information of each modality. This study evaluated the accuracy of the combined femoral model in terms of anatomical inspection. METHODS Six normal porcine femora (180 +/- 10 days, 3 lefts and 3 rights) with ball markers were scanned by CT and MRI. The 3D/3D registration was performed by two methods, i.e. the landmark-based 3 points-to-3 points and the surface matching using the iterative closest point (ICP) algorithm. The matching accuracy of the combined model was evaluated with statistical global deviation and locally measure anatomical contour-based deviation. Statistical analysis to assess any significant difference between accuracies of those two methods was performed using univariate repeated measures ANOVA with the Turkey post hoc test. RESULTS This study revealed that the local 2D contour-based measurement of matching deviation was 0.5 +/- 0.3 mm in the femoral condyle, and in the middle femoral shaft. The global 3D contour matching deviation of the landmark-based matching was 1.1 +/- 0.3 mm, but local 2D contour deviation through anatomical inspection was much larger as much as 3.0 +/- 1.8 mm. CONCLUSION Even with human-factor derived errors accumulated from segmentation of MRI images, and limited image quality, the matching accuracy of CT-&-MRI combined 3D models was 0.5 +/- 0.3 mm in terms of local anatomical inspection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Diagnostic Value of CT Scan and MRI in Brain Tumors and Comparison with Biopsy

Abstract Background Cerebral neoplasm arises from brain, spinal cord and meningeal cells. Not only malignant cerebral neoplasm also benign tumor could lead to death due to mass effect on vital structures. Access to these tumors is difficult, and MRI and CT scan could be helpful in determining anatomical location of tumors and distinction of malignant from benign. Objective For better and ea...

متن کامل

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

Skeletal Tuberculosis Presenting as a Small Cystic Lesion in the Medial Femoral Condyle

  Skeletal tuberculosis is an unusual disease involving bone and joints and it may have different manifestations. This report introduces a 25-year-old woman suffering from chronic knee pain without any response to conservative treatments for one year. X-ray was normal but CT-scan and MRI indicated a small lesion in medial condyle of the femur. The patient underwent percutaneous CT-guided biopsy...

متن کامل

تغییرات طبیعی سلاتورسیکا و محتویات آن در CT و MRI و مرور منابع تحقیقاتی

Background and Aim: With daily improvement of diagnostic modalities, accurate knowledge of anatomy and microanatomy is necessary and important, for better diagnosis of pathologic problems from normal variations. One of this very important anatomical sites is sella and suprasellar zones, where sensitive elements is noted. CT and MRI is very helpful in diagnosis and management of diseases as well...

متن کامل

Combined Positron Emission Tomography and Magnetic Resonance Imaging: A Technical Challenge

A clinical prototype of combined Combined Positron Emission Tomography (PET) / Computed Tomography (CT) system went under the clinical evaluation in 1998. After three years of research and clinical evaluation first clinical combined PET/CT system was installed in a clinic in 2001 [1-3]. Gradually clinical utilization of combined PET/CT increased tremendously particularly in oncological imaging ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioMedical Engineering OnLine

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2008