Finite element analysis of biomechanical interactions of a tooth-implant splinting system for various bone qualities.

نویسندگان

  • Chun-Li Lin
  • Shih-Hao Chang
  • Jen-Chyan Wang
چکیده

BACKGROUND The splinting of an implant and tooth is a rational alternative in some clinical situations. The complex biomechanical aspects of a tooth-implant system are derived from the dissimilar mobility between the osseointegrated implant and the tooth. The aim of this study was to analyze the biomechanics in a tooth-implant splinting system for various bone qualities with different occlusal forces using non-linear finite element (FE) analysis. METHODS A 3D FE model containing one Frialit-2 implant splinted to the mandibular second premolar and a simplified bony segment was constructed. Four bone quality categories were established by varying the elastic parameters assigned to the bone volumes. Contact elements (frictional surface) were used to simulate the realistic frictional interface condition within the implant system. The stress distributions in the splinting system were observed for four loading types. RESULTS The simulated results indicated that the lateral occlusal forces significantly increased the implant system (sigmaI, max), alveolar bone (sigmaAB, max) and prosthesis (sigmaP, max) stress values when compared with the axial occlusal forces. The sigma1, max and sigmaP, max values did not exhibit significant differences between the four bone qualities. Conversely, the sigmaAB, max values increased with reduction in bone quality, in particular for type IV bone quality. The sigmaI, max, sigmaAB, max and sigmaP, max stress values were significantly reduced in centric or lateral contact situations once the occlusal forces on the pontic were decreased. CONCLUSIONS This study suggests that implants connected to natural teeth should be used with caution in softer bone regions. Utilizing occlusal adjustment to minimize the occlusal loading force on the pontic could reduce the stress/strain values in the splinting system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

متن کامل

مطالعه تنش‌های اطراف ایمپلنت به روش اجزای محدود در بریج‌های با ساپورت دندان/ایمپلنت در شرایط اتصال سخت و غیرسخت در پروتزهای سمان شونده

Background and Aims: Freestanding fixed partial prosthesis is considered the first choice whenever possible. However, anatomical limitations for implants and other reasons may create situation in which it would be preferable to connect the implants to teeth. A biomechanical dilemma in a tooth/implant-supported system comes from dissimilar mobility. This disparity cause the bridge to function as...

متن کامل

Biomechanical Outcomes of Tooth-Implant-Supported Fixed Partial Prostheses (FPPs) in Periodontally Healthy Patients using Root Shape Dental Implants

Background: Connecting an osseointegrated implant and a natural tooth is a treatment alternative for partially edentulous patients in some clinical situations. The main issue of a connected tooth-implant system is derived from the dissimilar mobility patterns of the osseointegrated fixtures and natural abutments causing potential biomechanical problems within the entire system. Purpose: The aim...

متن کامل

The effect of implant angulation and splinting on stress distribution in implant body and supporting bone: A finite element analysis

OBJECTIVE The aim of this study was to investigate the influence of implant crown splinting and the use of angulated abutment on stress distribution in implant body and surrounding bone by three-dimensional finite element analysis. MATERIALS AND METHODS For this study, three models with two implants at the site of mandibular right second premolar and first molar were designed (1): Both implan...

متن کامل

Effect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis

This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chang Gung medical journal

دوره 29 2  شماره 

صفحات  -

تاریخ انتشار 2006